A - 141
Appendices
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
A-3 Sysmac Error Status Codes
A
A-3-2 Error Description
Event name Interface Output Function Number Error 1 Event code 3849 0000 hex
Description There is an undefined number specification in the output signal (OUTM1) function allocation.
Source
EtherCAT Master Function Module
Source
details
Slave
Detection
timing
When
establishing
communications
after turning ON
power to the
slave or when
transferring
EtherCAT
Configuration
Setup
Error
attributes
Level
Minor fault
Recovery
Error reset
(after cycling slave
power)
Log category
System
Effects
User program
Continues. Operation Power drive circuit is OFF for relevant slave.
Indicators
EtherNet/IP NET RUN EtherNet/IP NET ERR EtherNet/IP LINK/ACT
––
System
-defined
variables
Variable Data type Name
None
Cause and
correction
Assumed cause Correction Prevention
There is an undefined number
specification in the output signal
(OUTM1) function allocation.
Allocate the functions to the
connector pins using only the
numbers that are defined.
Allocate the functions to the
connector pins using only the
numbers that are defined.
Attached
information
None
Precautions/
Remarks
“33” is displayed on the Servo Drive front panel and F433 is given as the AlarmCode (4001 hex).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-KN10F-ECT-L and is the answer not in the manual?

Omron R88D-KN10F-ECT-L Specifications

General IconGeneral
BrandOmron
ModelR88D-KN10F-ECT-L
CategoryServo Drives
LanguageEnglish

Related product manuals