General-purpose Basic Switch Z F-177
Limit
Switches
Note: Do not use the M12 mounting screw and the case mounting hole at the same time, or the case may be damaged.
Note: Do not use the M12 mounting screw and the case mounting hole at the same time, or the case may be damaged.
Note: Do not use the M12 mounting screw and the case mounting hole at the same time, or the case may be damaged.
OF max.
RF min.
PT max.
OT min.
MD max.
5.30 N {541 gf}
1.12 N {114 gf}
1.8 mm
5.5 mm
0.06 mm
OP 21.8±0.8 mm
OF max.
RF min.
PT max.
OT min.
MD max.
5.30 N {541 gf}
1.12 N {114 gf}
1.8 mm
3.58 mm
0.06 mm
OP 33.4±1.2 mm
OF max.
RF min.
PT max.
OT min.
MD max.
5.30 N {541 gf}
1.12 N {114 gf}
1.8 mm
3.58 mm
0.06 mm
OP 33.4±1.2 mm
Panel Mount Plunger
Z-15GQ55-B
8.35 dia.
4.2
+0.075
dia. hole
−0.025
16 dia.
4.36
+0.1
dia.
−0.05
(see
note 2)
11.9SR
(see note 1)
M12 × 1
Mounting screw
Two hexagonal nuts
(2 t × 14 width across flats)
Two lock nuts
(2 t × 15.6 width
across flats)
Note: 1.
Stainless-steel plunger
2.
Imperfect screw part with a maximum
length of 1.5 mm.
Panel Mount Roller Plunger
Z-15GQ2255-B
(see note)
4.2
+0.075
dia. hole
−0.025
16 dia.
4.36
+0.1
dia.
−0.05
12.7 dia. × 4.8
(stainless-steel roller)
Two hexagonal nuts
(3 t × 17 width
across flats)
M12 × 1
mounting screw
Note:
Imperfect screw part with a
maximum length of 1.5 mm.
Panel Mount Cross Roller Plunger
Z-15GQ2155-B
12.7 dia. × 4.8 (stainless-steel roller)
(see note)
4.2
+0.075
dia. hole
−0.025
16 dia.
4.36
+0.1
dia.
−0.05
Two hexagonal nuts
(3 t × 17 width across flats)
M12 × 1
mounting screw
Note: Imperfect screw part with a
maximum length of 1.5 mm.