EasyManuals Logo

Omron D4N Series User Manual

Omron D4N Series
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Safety Limit Switch
D4N
Upgraded Safety Limit Switches Based
on the Popular D4D, Providing a Full
Lineup Conforming to International
Standards
Lineup includes three contact models with 2NC/1NO and 3NC
contact forms in addition to the previous contact forms 1NC/
1NO, and 2NC. Models with MBB contacts are also available.
M12-connector models are available, saving on labor and
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1, and EN81-2 (slow-action models
only).
Lineup includes both slow-action and snap-action models with
Zb contacts.
Certified standards: UL, EN (TÜV), and CCC
Model Number Structure
Model Number Legend
1. Conduit size
1: Pg13.5 (1-conduit)
2: G1/2 (1-conduit)
3: 1/2-14NPT (1-conduit)
4: M20 (1-conduit)
5: Pg13.5 (2-conduit)
6: G1/2 (2-conduit)
7: 1/2-14NPT (2-conduit)
8: M20 (2-conduit)
9: M12 connector (1-conduit)
2. Built-in Switch
1: 1NC/1NO (snap-action)
2: 2NC (snap-action)
A: 1NC/1NO (slow-action)
B: 2NC (slow-action)
C: 2NC/1NO (slow-action)
D: 3NC (slow-action)
E: 1NC/1NO (MBB contact) (slow-action)
F: 2NC/1NO (MBB contact) (slow-action)
3. Head and Actuator
20: Roller lever (resin lever, resin roller)
22: Roller lever (metal lever, resin roller)
25: Roller lever (metal lever, metal roller)
26: Roller lever (metal lever, bearing roller)
2G: Adjustable roller lever, form lock (metal lever, resin roller)
2H: Adjustable roller lever, form lock (metal lever, rubber roller)
31: Top Plunger
32: Top Roller Plunger
62: One-way roller arm lever (horizontal)
72: One-way roller arm lever (vertical)
80: Cat whisker
87: Plastic rod
RE:Fork lever lock (right operation)
LE: Fork lever lock (left operation)
Note: Contact your sales representative for details on models
with safety standard certification.
Be sure to read the “Safety Precautions” on page 18
and the “Precautions for All Safety Limit Switches” .
1 2 3
D4N-@@@@
http://www.ia.omron.com/
1
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

Other manuals for Omron D4N Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron D4N Series and is the answer not in the manual?

Omron D4N Series Specifications

General IconGeneral
Voltage Rating250 VAC, 30 VDC
Ingress ProtectionIP67
Actuator TypePlunger
Current Rating10 A
Housing MaterialPlastic
CategorySwitch
Connection MethodScrew terminals
Operating Speed0.05 mm/s to 0.5 m/s
StandardsUL 508
Mechanical Life15, 000, 000 operations minimum
Electrical Life500, 000 operations
Contact Configuration1NC/1NO, 2NC