EXHAUST
SYSTEM
With the generator set operating, inspect the entire
exhaust system including the exhaust manifold, muffler,
turbocharger and exhaust pipe. Visually and audibly
check for leaks at all connections, welds, gaskets, and
joints.
Make sure exhaust pipes are not heating sur-
rounding areas excessively. If any leaks are detected,
have them corrected immediately.
AWARNING
Inhalation of exhaust gases can
result in severe personal injury or
death. Inspect exhaust
system
audibly and visually
for
leaks daily. Repair any leaks immediately.
FUEL
SYSTEM
With the generator set
operating,
inspectthe fuel supply
lines,
filters, and fittings for leaks. Check any flexible
sections for cuts, cracks, and abrasions and make sure
they are not rubbing against anything that could cause
breakage.
AWARNING
Leaking fuel will create a fire hazard
that can result in severe personal
injury or death if ignited by a spark. If any leaks are
detected, have them corrected immediately.
DC
ELECTRICAL
SYSTEM
With the generator set off, check the terminals on the
battery for clean and tight connections. Loose or
corroded connections create resistance that can hinder
starting.
Clean and reconnect the battery cables if loose.
Always connect the negative battery cable last.
AWARNING
Ignition of explosive battery gases
can cause severe personal
injury.
Dp
not smoke while servicing batteries.
COOLING
SYSTEM
When the engine is first started, remove the pressure
cap and monitor the coolant level. As trapped air is
expelled from the
system,
the coolant level will drop and
additional coolant should be added. Replace the
pressure cap when the coolant level is stable.
AWARNING
Contact
with
hot coolant can result in
severe burns. Allow cooling system
to cool before releasing pressure and removing the
radiator cap.
MECHANICAL
ADJUSTMENTS
With the generator set stopped, check for loose belts
and fittings, leaking gaskets and hoses, or any signs of
mechanical damage. If any problems are found, have
them corrected immediately.
With the set running, listen for any unusual noises that
may indicate mechanical problems and check the oil
pressure frequently. Investigate anything that indicates
possible mechanical problems. Refer to the Operators
Manual for any necessary adjustments.