1645 Chapter 2
User manual Installing and connecting the 1645
31
2.9 Powering up the 1645
To power up the 1645, always follow these steps:
Connect the DC power input jack from the power supply to the DC power input of the rear panel of
the device.
Connect the power supply to the AC mains.
Self test
A few seconds after the power is switched on, the 1645 performs a series of self-tests and loads the
software into memory (RAM), during which the PWR LED on the front panel blinks.
At the end of the software loading, after about 30 seconds, if:
the PWR LED remains green continuously, it means that the software initialization was successful.
the PWR LED blinks, it means that:
- the software was absent,
or,
- there was an error during the software loading process.