Page 43
Loca
l / W
ide A
rea N
et
work
To c
onn
ec
t to
an H
MS 1100 c
ont
r
o
ll
er o
n
a lo
cal netw
ork using H
MS
PC Acc
ess
,
under
Con
fi
gur
e >>
Netw
ork
en
ter
the
c
o
nt
ro
ll
e
r’s
IP
a
d
d
re
s
s:
(i.e
.
10
.0.
0.2
30
)
T
o c
o
n
n
ec
t to
an H
MS 1100 c
ont
r
o
ller
fr
om th
e In
tern
et
usin
g HMS PC A
ccess,
under
Con
fi
gur
e >>
Netw
ork
en
ter
the
public IP
add
r
es
s:
(i.e. 134
.42.112.8)
50
52
Table of Contents
Default Chapter
3
Table of Contents
3
Introduction
9
Underwriter's Laboratories (UL) Listing
9
Overall Description
10
Console Operation
10
Normal Top-Level Display
11
Display Menus
11
Main Menu
12
Error Beeps
12
Trouble Beeps
12
Confirmation Beep
13
Cancel
13
Time out
13
Areas
13
HMS 1100 Maintenance
13
Security System Operation
14
Disarming the Security System and Silencing Alarms
14
Arming the Security System
14
Using Shortcut Keys
15
Quick Arm
16
Bypassing Zones
16
Auto-Bypass
16
Restoring Zones
16
Goto
17
What to Do When You Come Home
17
What Happens When the Alarm Is Activated
17
Burglar Alarm Activated
17
Fire Alarm Activated
18
Gas Alarm Activated
18
Emergency Keys
18
Police Emergency
19
Fire Emergency
19
Auxiliary Emergency
19
Duress Code Entered or Duress Alarm Activated
19
Alarm Reset
19
Alarm Cancel
19
Trouble Indications
20
Codes
20
Master Code
20
Manager Code
21
User Code
21
Duress Code
21
Panic Switches
21
Area Arming
21
GOTO Area
22
Testing Your System
23
Control
24
Control Commands
24
ALC Switch Modules
24
ALC Module Types
24
X-10 Modules
24
House Codes
25
Unit Numbers
25
Scrolling through Names
26
Controlling Units
27
Dimming and Brightening
27
Lighting Level
27
Ramp Command
28
Scene Command (Compose)
28
Timed Commands
28
Status of a Unit
29
Internal Flags
29
Controlling Outputs
29
All on / off
29
All Lights on
30
All off
30
Leviton Scene Control
30
Scene
30
Scene Commands
30
Scene Set Command
31
Scene on Command
31
Scene off Command
31
Buttons
31
Temperature Control
32
HMS Thermostats
32
Freeze Alarms
34
Outdoor Temperature
34
Temperature Control of Appliances
34
Temperature Alarms
34
Humidity
34
Status
35
Event Log
37
Show Events
37
Messages
38
Record Memo Message
38
Play Memo Message
38
Clear Text Messages
38
Message
39
Show Message
39
Log Message
39
Clear Message
39
Say Message
39
Phone Message
40
Send Message (Pro-Link)
40
Telephone Control
41
Telephone Interface
41
In-House Phones
41
Remote Phones
41
Phone Access Denied - Remote Lockout
42
Alternate Method
42
Main Menu
42
Control
43
Security
43
GOTO Area
43
Button
43
All
43
Temperature
43
Status
44
Events
44
Message
44
Playing and Recording a Message
45
Paging and Listening
45
Playing and Recording a Custom Phrase
45
Playing and Recording the Address
46
Good-Bye
46
Panic Button over the Phone (# # # # # #)
46
Emergency Dial-Out
46
Digital Dialer
46
Voice Dialer
47
How the HMS 1100 Voice Dialer Works
47
What the HMS 1100 Voice Dialer Does
47
What You Hear - if Your HMS 1100 Calls You
48
Entering the Code
48
PC Access
48
Built-In Ethernet Port
49
Controller IP Address, Port Number, and Encryption Key
49
Connecting to Network Via PC Access
49
Dynamic DNS
50
Setup
52
Configuration and Advanced Control Programming (ACP)
52
Set up Codes
52
Authority Level
52
Master
52
Manager
52
User
52
Access Areas
52
Duress Code
53
Set up Time
53
Advanced Control Programming (ACP)
54
Add Programs
54
Show Programs
54
Delete All Programs
56
Edit Programs
56
Edit Programs When
57
Times Programs
57
Button and Event Programs
58
Control Unit Event / ALC Switch Press Event Buttons
58
Security Mode Event Buttons
58
Zone Event Buttons
59
All On/Off Event Buttons
60
Alarm Event Buttons
60
X-10 Event Buttons
60
Miscellaneous Event Buttons
61
Message Event Buttons (Pro-Link)
61
Edit Program Command
62
Program Control Commands
62
Program Security Commands
62
Program Button Commands
63
Program All on / All off Commands
63
Program Temperature Commands
63
Program Energy Cost
63
Program Message Commands
63
Edit Program Condition
64
Program Control Conditions
64
Program Security Mode Conditions
64
Program Zone Conditions
64
Program Time Clock Conditions
65
Program Other Conditions
65
Set up Dial
66
Telephone Access
66
Answer Outside Call
66
Remote Commands
66
Rings before Answer
66
Dial Type
66
My Phone Number
66
Dial out Number 1
67
Dial out Numbers 2-8
67
Dial Order
67
Set up Arming
68
Entry Delay
68
Exit Delay
68
Audible Exit Delay
68
Entry/Exit Chime
68
Perimeter Chime
68
Enable Quick Arm
69
Enable Auto Bypass
69
All on for Alarm
69
Beep on Trouble
69
Set up Miscellaneous
69
High Security Mode
69
Announce Alarms
69
Enable Freeze Alarm
70
Flash for Alarm
70
X-10 House Code 1 Format
70
X-10 House Codes 2-16 Format
70
House Code 1 X-10 All off
70
House Code 1 X-10 All on
70
House Codes 2-16 X-10 All off
71
House Codes 2-16 X-10 All on
71
Time Clocks
71
Latitude, Longitude, and Time Zone
72
Daylight Savings
72
Controller IP Address
73
Controller Port Number
73
Encryption Key
74
Set up Names
74
Set up Voice
75
Set up Address
75
Underwriter's Laboratories Requirements
76
Fire Escape Planning
76
Federal Communication Commission Notice
77
Canadian Industry Canada Notice
78
Appendix A - Dial out Planner
79
Instructions to Called Party
80
Appendix B - Text Description Character Codes
81
Appendix C - Voice Description Codes
82
Notes on Custom Phrases
85
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the OnQ Technologies HMS 1100 and is the answer not in the manual?
Ask a question
OnQ Technologies HMS 1100 Specifications
General
Brand
OnQ Technologies
Model
HMS 1100
Category
Security System
Language
English