onsenproducts.ca
800-996-5559
ENGLISH
TROUBLESHOOTING
WATER HEATER DOES NOT TURN ON AND NO AUDIBLE CLICKS
Ensure the ON/OFF switch at the bottom of the water heater is in the
ON position.
Ensure the 2 “D” batteries are in working condition and inserted proper-
ly in the correct position. If using the 12 volt feature for ignition, ensure
the 12 volt accessory is connected properly on both ends (water heater
and 12 volt power source). Ensure the 12 volt power source (ex: 12 volt
battery) is not depleted and working properly.
Ensure the incoming water hose is connected to the water inlet of the
water heater and the outgoing water hose (shower set) is connected to
the water outlet. The water heater will not ignite if the connections are
reversed.
Check for debris in the water heater’s water inlet. The presence of debris
in the water inlet screen may aect the incoming water pressure, which
could prevent the ame from igniting.
Verify the water pressure. The primary cause of non-ignition is insu-
cient water pressure. The water heater requires a minimum 10 PSI of
sustained water pressure to ignite the burner. Municipal water pressure
is commonly rated at 60 PSI while most water pumps are rated at 40 –
60 PSI.
If using a water pump for water pressure, try connecting the water heat-
er to municipal water pressure instead. Water pumps can sometimes
provide mixed results based on the specications and the connection