OVS-01GT Quick Reference Guide
1. If used for Activation, go to section 2. If used for Vehicle protection, go to section 3.
2. If Activation mode, find the installation location by referring the following chart.
Installation height has to be 500mm(19.69” ) from the ground.
3. If Vehicle protection mode, find the installation location by referring the following chart. Always recommended to install
700mm(70.87” ) far from barrier or slide gate. Installation height has to be 500mm(19.69” ) from the ground.
[1] Make holes to mount the sensor.
[2] Run a cable thru the post or pole.
[4] Mount the base using 4 screws.
[5] Connect wires.
Power Supply 12-24VDC
Non-Voltage Relay Output N.O. / N.C. Switchable
30VDC 0.3A or less (resistance load)
Applicable Wire
Single conductor: 0.5-1.2mm (equivalent to CPEV)
Stranded wire: 0.3-2.0sq
Signal GNP
Input Active High / Low Switchable
Power Output Input
5.
Set the Microwave maximum range and Sensor mode as follows:
Activation : 5m(16.4’ )
Vehicle protection : 3.5m(11.48’ ) (factory default setting)
Usually, other settings can be default settings.
For detailed settings, refer to Advance Installation on page 17.
Sensor Mode
Output
4
4.5
5
5.5
2
2.5
3
3.5
N.O.
N.C.
Activation
Vehicle
Protection
Microwave Maximum Range (m)
Sensor Mode button
Microwave Maximum
Range botton
6. Perform sensor calibration in order to memorize the
background of the detection area. Ensure no
pedestrians or vehicles are present.
Calibration Area Check
Standby
Area Check
Detection
Calibration
Calibration Error
1. Press the Calibration button.
2. Operation indicator blinks in blue.
7. System operation check.
Check the entire coverage area by using actual vehicle.
Left side of the lane
Center of the lane
Right side of the lane
[6] Attach the sensor body to the base
and adjust the sensor angle.
8. Put the front cover on the top of the base first, and attach it
while spreading it open and pushing down the front cover.
9. Tighten the front cover retaining screw.
[3] Loosen the retaining screws on the bottom
of the front cover and remove the front
cover, detach the sensor unit.
Hold here and
pull forward
Vehicle
Path
1800mm
(70.87in.)
Gate Bar
Operation Type: Activation
Installation Height of 500mm(19.69in.)
Island
45°
Ticket Vending
Machine
150m
m
(5.90in.)
4. Install the sensor, wire it and apply power.
GL+588(23.15)
Mounting
Pitch 32±1
(1.26±0.04)
Mounting Pitch
70±1(2.76±0.04)
5(0.20)
M4 Tap
Depending on the
cable diameter
[Unit : mm(inch)]
Gate
Operation Type: Vehicle Protection
Installation Height of 500mm(19.69in.)
30°
100
mm(3.94in.)
1100
mm
(43.3in.)
Secure side
Public side
Vehicle
Path
Gate
90°
100
mm(3.94in.)
90°
Operation Type: Vehicle Protection
Installation Height of 500mm(19.69in.)
Secure side
Public side
700
mm
(27.56in.)
700
mm
(27.56in.)
Vehicle
Path
90°
Gate Bar
150m
m
(5.90in.)
Island
700
mm(27.56in.)
Operation Type:Vehicle Protection
Installation Height of 500mm(19.69in.)
Ticket Vending
Machine
Vehicle
Path
500mm(19.69in.)
500mm(19.69in.)
Barrier Gate Slide Gate
Barrier Gate Slide Gate
3. Step away from sensor and
outside detection area.
4. Green LED lights when done
correctly.