(1) Connector
(2) Sensitivity Potentiometer
(3) Mode Setting Switches
( Area Depth Adjustment, Auto Learning Timer,
Frequency, Rain Mode, Snow Mode )
(4) Area Width Switch
(5) Threshold Area Angle Screw
(6) Threshold Area Angle Gauge
(7) Swing Area Angle Gauge
(8) Swing Area Angle Screw
(9) Mounting Holes
(10) Operation Indicator
OPERATION INDICATOR
THRESHOLD AREA
SENSITIVITY
POTENTIOMETER
MaxMin
SWING AREA
SENSITIVITY
POTENTIOMETER
0deg
+5deg
‑5deg
DEEP
SHALLOW
SWING AREA DEPTH ADJUSTMENT
0deg
+5deg
‑5deg
DEEP
SHALLOW
FREQUENCY SWITCH
1
3
2
3
Each number of Area
can be eliminated
by using each dip‑SW.
AREA WIDTH SWITCH
OA-603
DEEP
SHALLOW
DEEP
SHALLOW
DEEP
PATTERN
SHALLOW
PATTERN
THRESHOLD AREA DEPTH ADJUSTMENT
AUTO LEARNING TIMER
1 2
15SEC.
1 2
1 2
1 2
6
DEEP
6
SHALLOW
AREA DEPTH
MaxMin
5
NORMAL
5
SNOW
SNOW MODE
30SEC. 60SEC.120SEC.
:Stand‑by
:Doorside Det.
Green
Red Blink
Red
Yellow Blink
:Teaching
:Presence Det.
OPERATION INDICATOR
4
NORMAL
4
RAIN
RAIN MODE
Active Inactive
1 2 3
4 5
6 7 8
CONNECTOR
CONNECTOR
DEEP
PATTERN
SHALLOW
PATTERN
HINGE SIDE
7
RIGHT SIDE
7
LEFT SIDE
SENSOR SIDE
SWING SIDEAPPROACH SIDE
8 8
These DipSW(7,8) are only for door mount.
5728770
56.5(2 1/4")
275(10 3/4")
32(1 1/4")
Model : OA-603
Cover color type
: Black , Slilver
Mounting Height : 2.0m (6’7”) to 2.5m (8’2”)
Detection Area : See the chart in “ADJUSTMENT”.
Detection Method : Active Infrared Reflection
(Presence Detection Type)
Detection Angle : Threshold Area ±5
(Inside & outside)
Adjustments :Swing Area ±5
(Inside & Outside)
Operation Indicator :Green : Stand-by
Blinking Red : Threshold Area Detection Active
Red : Swing Area Detection Active
Blinking Yellow :Learning
OUTER DIMENSIONS
SPECIFICATIONS
[mm (inch)]
248 (9 3/4”)
Operation Indicator
Insure proper setting of Mode switch #8 indicating Approach side or Swing side sensor.
ELITE
Swing Door
Door Mounting Sensor
(1)
(1)
(3)
(4)
(2)
(6) (7) (8)
(9)
(9)
(10)
MANUFACTURER'S STATEMENT
For ease of installation and proper operation read thru this manual (especially
WARNING
CAUTION
NOTE
) prior to installing and adjusting the sensor system.
Failure to read and follow the instructions in this manual may cause improper sensor operation resulting in serious injury or death.
This product is a non-contact activating switch intended for door mounted of an automatic door.
Do not use it for any other applications; otherwise proper operation and safety cannot be guaranteed.
1.Set door speeds and verify proper operation of door manufacturer’s equipment prior to applying power to the sensor system.
2.Do not install the sensor where it might be directly sprayed with rainwater.
3.Verify proper wiring prior to applying power to the sensor system to prevent damage to equipment.
4.When setting the sensors area pattern, make sure there is no traffic around the installation site.
5.Do not attempt to rebuild or repair sensor heads or control unit. Contact an address in this manual for replacement products.
6.Only use the sensor as specified in the supplied instructions.
7.Walk test the installation to verify operation is in compliance with all local laws, codes and standards of your country.
8.Upon completion of installation and adjustments, instruct the owner/operator on proper operation of the door and sensor system.
Identify any switches/breakers that will place the door out of service when unsafe or improper operation is identified.
Current Draw : 120mA Max
Response Time : < 0.3 second
Operating Temperature : -20
C
to +55 C (-4 F to +131 F)
Weight : 230g (8.2oz.)
Accessories : 1 Sensor Cable 0.2m(7”)
9 Mounting screws
1 Operation Manual
3 Mounting Template
(5)
WARNING
CAUTION
NOTE
Disregard of warning may cause the improper use causing death or serious injury of person.
Special attention for the setting and adjustment of section of this symbol is required.
Disregard of caution may cause the improper use causing injury of person or damage to
object.
5913001 2008.3
1-1

Questions and Answers

  • S
    Shelly WellsAug 11, 2025
    Why Optex OC-904C Accessories will not complete initial setup?
    • F
      fmooreAug 11, 2025
      If your Optex accessories are not completing the initial setup, it might be due to incorrect OC-904 dipswitch settings. Check the Connection Matrix for the proper settings. Also, inspect the yellow wires from the OC-904 to the door control for poor or improper connections, again referring to the Connection Matrix. Finally, ensure proper voltage on the red and black wires of the OC-904, with positive voltage on the red wire at hold open and 0 voltage at the closed position.
  • D
    Donna MoralesAug 16, 2025
    What to do if Optex OC-904C have no safety on swing side at full closed?
    • T
      Tracey MoyerAug 16, 2025
      If there's no safety on the swing side of your Optex accessories when fully closed, check for poor or improper connections of the blue wires from the OC-904 to the door control. Also, verify that the OC-904 dipswitches are set correctly. Finally, ensure that the area width dipswitches on the right bank of the OA-603 are properly set.
  • C
    Cheryl RamirezAug 21, 2025
    What to do if Optex OC-904C Accessories door remains open?
    • B
      Brian OrtizAug 21, 2025
      If the Optex Accessories door remains open, verify the OC-904 dipswitch settings. For knowing act applications, check the purple wires from the OC-904 to the activation device for poor or improper connections. Also, verify the proper wiring of the door equipment's on/off/hold switch.
  • K
    Kaitlyn GregoryAug 27, 2025
    What to do if Optex OC-904C have no stall on swing side while door is opening?
    • M
      Mary JohnstonAug 27, 2025
      If there is no stall on the swing side of your Optex accessories while the door is opening, check for poor or improper connections of the green wires from the OC-904 to the door control. Also, verify the OC-904 dipswitches are set correctly. Finally, ensure the area width dipswitches on the right bank of the OA-603 are properly set.
  • M
    melissa99Aug 30, 2025
    What to do if Optex Accessories have no activation and/or no reactivation on closing cycle?
    • M
      martinezjoshuaAug 31, 2025
      If your Optex accessories have no activation or reactivation on the closing cycle, verify the proper connection and output of the yellow wires from the OC-904 to the door control or on/off/hold switch. Also, verify the proper settings of the OC-904 dipswitches. For knowing act applications, check for poor or improper connections of the purple wires from the OC-904 to the activation device.
  • T
    Tonya SmithNov 5, 2025
    What to do if Optex Accessories have intermittent recycle or intermittent stalling?
    • S
      Scott OwensNov 5, 2025
      If your Optex accessories experience intermittent recycling (ghosting) or stalling, consider these potential causes. If the door ghosts several times on the first activation, this is normal for 15% of installations and should resolve after the first activation. Ensure the OA-603 sensor head is mounted flush on the door. Adjust the threshold and swing area angles to +5 degrees. Also, ensure positive voltage on the red wire at hold open and 0 voltage at closed position. If stalling is caused by traffic or objects near guide rails, set switch 6 on the left bank dipswitch of OA-603 to the on/up (shallow) position. Verify the area width dipswitch settings on the right bank of the OA-603. Lastly, reposition the loop assembly so the loop center coupler does not rest on the door at any point of do...

Summary

Manufacturers Statement

Specifications

Outer Dimensions

Installation Guide

Top View Diagram

Diagram illustrating sensor placement for different door configurations.

Sensor Setting and Adjustment

Guidance on dipswitch configuration and angle adjustments for optimal performance.

DipSwitch Settings (1-4) Configuration

Specific dipswitch settings for various door sizes and configurations.

Adjustments and Settings

Sensitivity Adjustment

How to adjust threshold and swing area sensitivity potentiometers.

Mode Dipswitch Functions Overview

Overview of dipswitch functions for timer, frequency, rain, and snow modes.

Frequency Setting for Interference

Explanation of interference prevention using frequency settings.

Environmental Mode Settings

Configuration for rain and snow conditions.

Side Identification Settings

Dipswitch settings for door hinge and sensor sides.

Area Depth Adjustment

How to adjust the detection area depth (shallow/deep).

Auto Learning Function

Checking and Setup

Initial Setup Process

Step-by-step guide to the sensor's initial setup and learning sequence.

Operation Check

Troubleshooting Guide

Common Issues and Solutions

Common issues, their causes, and recommended solutions for sensor problems.

OPTEX OC-904 C Sensor Controller

OC-904 C Specifications

Technical details of the OC-904C sensor controller.

OC-904 C Installation Wiring

Wiring and connection instructions for the sensor controller.

OC-904 C Adjustment Settings

Dipswitch settings for safety, stall, and activation functions.

OC-904 C Troubleshooting

OC-904 C Warning Indications

Explains operational indicators and error codes for the controller.

Optex OC-904C Specifications

General IconGeneral
BrandOptex
ModelOC-904C
CategoryAccessories
LanguageEnglish

Related product manuals