Optex Inc. - 1845 W 205th St. - Torrance, Ca. 90501 - 800-966-7839 SMDC-16 Program Manual 3440-0252 A4
Installer Program MenuInstaller Program Menu
1. System Times
1. Delay Times
1. Pre-Alarm Delay
2. Entry Delay
3. Exit Delay
4. AC Fail Delay
5. AC Fail Display
2. Cutoff Times
1. Bell 1
2. Bell 2
3. Relay 1
4. Relay 2
5. PGM 1
6. PGM 2
7. PGM 3
8. Listen-In
3. Self Test
1. Daily
2. Weekly
3. Time of Day
4. Self Test Code
5. Abnormal Test Code
6. Telco Test Report
7. Radio Test Report
4. Real Time Clock
1. Time Clock
1. Set Date
2. Set Time
2. Set by User
3. Display for User
4. Daylight Saving
2. Zone Configuration
1. Zone Configure
(Set Zone Number)
pre-defined YES/NO
1. Zone Type
2. Loop Type
3. Report Codes
1. Alarm
2. Trouble
3. Bypass
4. Cancel
5. Restore
4. Zone Name
5. Loop Response
6. Entry Delay
7. Zone Features
1. Silent Day/
Audible Night
2. Telephone
3. Radio
4. Bypass Allowed
5. Shunt Allowed
6. Display Armed
7. Walk Test
8. Monitor Mode
9. Auto Walk at Arm
8. Zone Outputs
1. Bell 1
2. Bell 1 Pulse
3. Bell 2
4. Bell 2 Pulse
5. Relay 1
6. Relay 2
7. PGM 1
8. PGM 2
9. PGM 3
9. Alarm Verify
2. Templates
(Set Zone Type)
1. Loop Response
2. Zone Features
1. Silent Day/
Audible Night
2. Telephone
3. Radio
4. Bypass Allowed
5. Shunt Allowed
6. Display Armed
7. Walk Test
8. Monitor Mode
9. Auto Walk at Arm
3. Zone Outputs
1. Bell 1
2. Bell 1 Pulse
3. Bell 2
4. Bell 2 Pulse
5. Relay 1
6. Relay 2
7. PGM 1
8. PGM 2
9. PGM 3
3. Cross Zoning
1. Cross Pair 1
2. Cross Pair 2
3. Cross Zone Timer
4. Number of Shunt Alm
5. Shunt Period
3. Receivers
1. Select Receiver #
1. Receiver 1
1. Telephone #
2. Account Numbers
1 Account # 1-40
1. Zones 1-8
2. Zones 9-16
3. Zones 17-24
4. Zones 25-32
5. Zones 33-40
2. Account # 41-80
1. Zones 41-48
2. Zones 49-56
3. Zones 57-64
4. Zones 65-72
5. Zones 73-80
3. Part Acct #’s
1. Part 1
2. Part 2
3. Part 3
4. Part 4
5. Part 5
6. Part 6
7. Part 7
8. Part 8
4. Common Acct. #
3. Format
2. Receiver 2
1. Telephone #
2. Account #’s
1 Account # 1-40
2 Account # 41-80
(Same as Rcvr 1)
3. Part Account #’s
(Same as Rcvr 1)
4. Common Acct. #
3. Formats
2. # of Telco Lines
3. Tel. Monitor Options
1. Monitor Both Lines
2. Keypad Audible
3. Bell 1 Output
4. Bell 2 Output
5. Relay 1 Output
6. Relay 2 Output
7. PGM 1 Output
8. PGM 2 Output
9. PGM 3 Output
4. Number of Dial Atts.
5. Dial Features
1. TouchTone/Rotary
2. Fallback on Rotary
3. Delay Before Dial
4. TLM fault time
5. Anti-Jam Time
6. Comm Fail Rpt Code
7. TLM Report Codes
1. TLM Fault
2. TLM Restore
8. Rcvr Report Options
1. Alarms
2. Open/Close
3. System
4. Partition #
1. Partition 1
2. Partition 2
4. System Options
1. Monitor Mode
1. Ack Required
2. Scroll Open Zones
3. Scroll Bypass
4. Silent Monitor Mode
5. Auto Monitor on
Disarm
6. PIN Entry Required
7. Monitor Mode Outputs
1. Bell 1 Output
2. Bell 2 Output
3. Relay 1 Output
4. Relay 2 Output
5. PGM 1 Output
6. PGM 2 Output
7. PGM 3 Output
2. Walk Test Mode
1. Bell 1 Output
2. Bell 2 Output
3. Relay 1 Output
4. Relay 2 Output
5. PGM 1 Output
6. PGM 2 Output
7. PGM 3 Output
3. System Features
1. Hist. View by User
2. O/C View by User
3. Silent Trouble
4. Not Used - Reserved
5. 50Hz/60Hz
6. AC/Crystal
7. Pwr Dly Time
before Zone Process
8. PIN Entry Required
for Zone Scan
9. Thresh of Bad Codes
4. System Messages
1. Top Line Display
1. Group/Part 1 Display
2. Group/Part 2 Display
3. Group/Part 3 Display
4. Group/Part 4 Display
5. Group/Part 5 Display
6. Group/Part 6 Display
7. Group/Part 7 Display
8. Group/Part 8 Display
2. Disarmed Nml Msg
3. Disarmed Abnnml Msg
5. Emergency
1. Emergency Enabled
2. Emergency Rpt
3. Bell Output 1
4. Bell Output 2
5. Relay Output 1
6. Relay Output 2
7. PGM Output 1
8. PGM Output 2
9. PGM Output 3
6. 2 Wire Smoke Loop
1. Alarm Report
2. Trouble Report
3. Smoke Restore
4. Smoke Reset Time
5. Alarm Verify.
6. Outputs
1. Bell 1 Output

Other manuals for Optex SMDC-16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Optex SMDC-16 and is the answer not in the manual?

Optex SMDC-16 Specifications

General IconGeneral
BrandOptex
ModelSMDC-16
CategoryCell Phone