Manual No. 25-ULGPMU01-01 Series OPT Handheld
CCD Scanner
Page 38
Case Conversion
ZZ
Start/End
Program
Menu
-[[-
YZ
No case
conversion
-Z[-
%
YW
Convert to
upper case
-ZX-
YX
Convert to
lower case
-ZY-
YY
Exchange case
-ZZ-
String Options - This section describes the alterations which can be made to the format of the transmitted data string.
Options available are:
* Case conversion
* Transmission of a code identifier
* Transmission of the code length
* Transmission of a prefix
* Transmission of a suffix
The prefix and/or suffix may include a code identifier and/or the code length.
String format:
prefix
bar code
data
suffix
Case conversion - The bar code may be converted to either lower of upper case or the case my be exchanged. These
options may be used if the user of a wedge has a preference to leave, for instance, the CAPSLOCK ON or if the host
required upper case characters only.