Example Settings: "Door Sequencer"
Landing Gear with Door Control
Door 1 remains open and closes after a delay of 8 seconds (gear retracted).
Door 2 closes automatically after a delay of 5 seconds (gear extended) or after a delay of 8
seconds (gear retracted).
RC1 input: gear switch ON – extended / OFF – retracted
20:RC1-MODE: NORMAL
21:RC1-PRESET: ON
RC3 output: gear valve or servo
30:RC3-MODE: RC1-DIRECT
31:RC3-WAIT-ON: 0.5 seconds
32:RC3-WAIT-OFF: 0.0 seconds
33:RC3-DIRECTION: any \
34:RC3-LOW: any |
35:RC3-MID: any > depending on the servo or valve
36:RC3-HIGH: any |
37:RC3-DELAY: any /
RC4 output: door 1, valve or servo
40:RC4-MODE: RC1-DIRECT
41:RC4-WAIT-ON: 0.0 seconds
42:RC4-WAIT-OFF: 8.0 seconds
43:RC4-DIRECTION: any \
44:RC4-LOW: any |
45:RC4-MID: any > depending on the servo or valve
46:RC4-HIGH: any |
47:RC4-DELAY: any /
RC5 output: door 2, valve or servo
50:RC5-MODE: RC1-TRIGGER
51:RC5-WAIT-ON: 5.0 seconds
52:RC5-WAIT-OFF: 8.0 seconds
53:RC5-DIRECTION: any \
54:RC5-LOW: any |
55:RC5-MID: any > depending on the servo or valve
56:RC5-HIGH: any |
57:RC5-DELAY: any /