6 | P a g e
Motor lead wire connections
Black lead wire connects to motor terminal as
shown single terminal side of motor.
White lead wire connects to motor terminal
as shown dual terminal side of motor.
(Note The 2
nd
top terminal and ground
terminal are open)
Intake Pivot Assembly
a. Intake pivot assembly stocked as shown.
Felt inlet seal is also carried separately.
5. Handle Detent
Located under the Motor / Fan Chamber
Assembly.
a. Remove base assembly section 1.
b. Remove motor / fan chamber assembly.
c. Remove handle detent 1 screw.
6. LED PCB
a. Remove base assembly section 1.
b. Disconnect LED PCB connection at main
PCB.
c. Remove two screws located in brushroll
cavity.
d. Turn unit over and lift upward on fascia to
remove.
e. Remove headlight lens lift up slightly on
cosmetic strip to allow clearance and remove
headlight lens.