EasyManua.ls Logo

Oreck ELEVATE Command UK30200COM - Motor, Intake Pivot, and Joint Assemblies; Handle and Fan Chamber Separation; Motor and Fan Chamber Disassembly; Joint Pivot Assembly Disassembly (UK30300)

Oreck ELEVATE Command UK30200COM
13 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 | P a g e
4. Motor Assembly / Intake Pivot Assembly
/Joint Assembly.
a. Remove base assembly section 1.
b. Separate lower handle from fan housing
assembly Rotate lower spine connector
CCW to remove.
c. Remove four screws that secure motor and
intake pivot assembly.
d. Lift motor / fan housing assembly out of
position.
e. Disconnect motor lead wires. Connector
may have a locking tab that must be
disengaged to allow removal.
f. To separate motor and fan chamber
assembly locate and remove fan nut by
securing the armature shaft and turning the
nut clockwise LH Thread.
g. Slide fan chamber assembly off of motor.
(UK30200 pictured).
Joint Pivot Assembly UK30300
a. Remove clamp assembly one screw.
b. Separate joint assembly halves two
screws.