Oreck LW100 Service Manual | 19
11. Fit the rope gaskets into the le joint. The photo below uses white fan housings to show
the paern that the grease should be administered. The thick line of grease is applied
primarily against the upper lip of the groove. The wavy line of grease should be smeared
on the at surface.
12. Fit the joint halves to the fan housing neck and secure with two screws.
13. Spread the clamp, bring it over the top of the joint and t to the boom of the joint.
14. Fit the clamp screw through and thread to the anvibraon nut. Hand ghten. Swivel the
joint all over to evaluatefuncon and ease of movement. The swivel joint to fan housing
will be s when just turning the joint. Be sure to test swivel acon with the unit fully
assembled before being concerned with joint swivel sness.