ORKEL MP 2000 - 5.2.3 Trouble shooting - Grease lubrication system

Default Icon
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
69

If you’re using grease of (extra pressure) there’s no need for special precau-
ons to be made regarding long me or winter storage. Perform a complete lubricaon service on the ma-
chine before storage. If you’re using a grease type according to lubricaon standards, but not having the an
corrosion eect, the system must be lled up with an corrosive oil. Regular motor oil would be sucient.

This operaon is easily done with a empty grease gun lled up with motor oil. Remove the piston and the
coil spring in the gun. Insert a empty grease cartridge and ll the grease gun while holding it vercally.
Aach the gun at the inlet on the main distributor and empty the gun into the system. (1/2 litre)
 -
  
Pump does not work Fuse defect
Cable from control unit to pump
broken
Problem with pump motor
Replace fuse
Replace electric cable
Replace pump motor
NOTE: Correct motor mounng
Pump is working but does not sup-
ply grease
Air pocket in pump
Level in reservoir is too low
Pump element not building up
pressure (no air pocket)
Bleed the pump
Rell the reservoir
Replace the pump element
No grease collar at all points of
lubricaon
Pump does not work
Clogging somewhere in the system
Refer to pump not working above.
See if grease is present on pres-
sure relief valve
No grease collar on several bear-
ings
A primary hose between main dis-
tributor and sub distributor is bro-
ken
Leakage in ngs
Replace hoses
Reghten ngs or replace
No grease collar on one bearing The hose serving the bearing is
defect.
Leakage in the ng
Replace hose
Reghten ngs or replace
Reduced pump speed High pressure in system
Low ambient temperature
Conduct a complete system check
Rum greaser manually 1 or 2 mes
to lubricate the system. Then start
up once more
Grease on pressure relief valve System pressure too high
Main distributor clogged
System clogged
Valve, relief spring defect
Check the system
Replace the distributor
Repair clogged bearing (housing)
Replace valve