Fasten the hook and loop fastener strap tightly.
When installed on mounting bracket S1820511-05, secure the hook and
loop fastener strap by pressing the two snaps.
If the ELT is fitted with a Water Switch Sensor (P/N S1820514-14), switch
the ELT to the “ARM” position.
(4) Sealing
When installed, It is possible to seal the ELT on its bracket to prevent misuse.
In case of an emergency, this seal must be weak enough to be broken manually
without any special tool.
ELT shall be installed with locking pin so that switch cannot be put in the “ON”
position (see Installation).
Install a seal using one of the two holes in the cover of the ELT and the
mounting bracket.