TROUBLESHOOTING
1. General
Procedure for fault isolation on board uses the visual indicator of the ELT’s front
panel. This visual indicator is activated by a self-test capability within the ELT.
2. Faults on Self-test
A. Visual Indicator
When the self-test is carried out, the number of flashes gives an indication of
the faulty parameter detected during the self-test.
(1)3+1 flashes
- Low battery voltage:
Check battery, refer to relevant CMM for test and repair.
(2) 3+2 flashes
- Low RF power:
Check 406 MHz power, refer to relevant CMM for test and repair.
(3) 3+3 flashes
- Faulty VCO locking (faulty frequency):
Check frequencies, refer to relevant CMM for test and repair.
(4) 3+4 flashes
- No identification programmed
Check programming, refer to relevant CMM for test and repair.
3. Other faults detected
A. Buzzer
(1)Buzzer does not operate
- Refer to relevant CMM for test and repair.
(2) Buzzer operates permanently when ELT in ARM mode
- Refer to relevant CMM for test and repair.
NOTE: for CMM download and other servicing instructions, refer to Service &
Support section of Orolia’s Web site: https://www.orolia.com/support/
Repair and battery replacement can only be carried out by PART 145 /
FAR 145 avionics workshops (or equivalent agreement according to
local regulations).
Additional approval from Orolia is required. Refer to Service Letter SL
S18XX50X-25-02 Maintenance Policy for KANNAD ELTs.