AutoFire® Kiln Controller User’s Guide
20
ELEC - Display electronics temperature Diagnostic Tool
The ELEC feature displays the electronics temperature of the AutoFire® Plus/Pro or AutoFire® UniTemp™
Kiln Controller. This feature is useful in monitoring the electronics temperature in severe environments or if
needed by factory technicians, kiln manufacturers, or kiln service technicians.
LoUn - Program Lock Mode Default Setting: Un (off)
The LoUn feature allows either a user program or a preset cone fire program to be locked into memory and to
disable program editing from the front panel. This feature is useful when only one particular program is used
over and over, and multiple people may be firing the kiln. When the program lock is set to 'Lo', only a delay
start can be selected, all other options can only be viewed, not changed. This feature is best used in a school or
contemporary studio where control of programming is needed. Refer to Appendix G to implement this feature.
The information on this page can be separated from the manual, if desired.
≡≡odl - Display Model Number Diagnostic Tool
The ≡≡odl feature displays the model number of the AutoFire®. 0000 is a Plus model, 0001 is a Pro model, and
0003 for a UniTemp™ model. When provided to factory technicians, kiln manufacturers, or kiln service
technicians, this information helps answer questions about features, operation or performance of your
AutoFire® Plus/Pro or AutoFire® UniTemp™ Kiln Controller.
Ser - Display Serial Number
The Ser feature displays the serial number of the AutoFire® kiln controller. When provided to factory
technicians, kiln manufacturers, or kiln service technicians, this information helps answer any questions about
features, operation, or performance of your AutoFire® Plus/Pro or AutoFire® UniTemp™ Kiln Controller.
SoFt - Display Software Version Diagnostic Tool
The SoFt feature displays the number of the software version of the AutoFire® Plus/Pro or AutoFire®
UniTemp™ Kiln Controller. When provided to factory technicians, kiln manufacturers, or kiln service
technicians, this information helps answer any questions about features, operation, or performance of your
AutoFire® Plus/Pro or AutoFire® UniTemp™ Kiln Controller.
rEtn - Return
The rEtn feature allows the user to exit Level 1 or Level 2 Options and return to the IdLE or the run state.
To return to the IdLE or run state, follow these steps:
Step Press Description Display
1 UP ARROW/ Scroll to the Return (rEtn) option. rEtn
RIGHT ARROW
2 ENTER Returns to the main display. LdLE