The Sentry Xpress 4.0 micro processor is manufactured by the
Orton Ceramic Foundation and displays the CE mark.
Hr./Min.
When Lit
HIGHER
°C
°F
When Off
When Lit
START/
STOP
LOWER
Program
Review
Run
MICRO PROCESSOR
TM
SENTRYXpress
4.0
Enter
Program
Skip Seg.
Add Hold
Change Temp.
T/C Offset
Alarm
Delay
Review
1
START/STOP Key
Starts and stops a firing.
Press after each
programming step. It works like the
Enter key on a computer.
Down Arrow Key
From press
.Theprogram
you have selected will ap-
pear one step at a time.
When appears,
press .Page4
From
press .
Enter delay time. Press
.Page4
During firing, press
. The program you
entered will appear one
step at a time. Page 4
Indicator
Lights
Temperature Display
Tempera
-
ture display is in °F.
Temperature display is in °C.
Seepage13forinstructions
on selecting °F and °C.
Time Display
:Sepa-
rates hours from minutes. Ex-
ample: Display shown above
is 1 hour and 30 minutes.
°C Display Dot
Cone Fire/Ramp-Hold Version
°F
°C
Sentry Xpress
Digital Temperature Controller
IM-222/8-07
Light is
on during pro
-
gramming.
Light is
on during pro
-
gram review.
Light
blinks during firing.
Up Arrow Key
From
press .Press
to select Cone-Fire or
Ramp-Hold. Pages 6, 8
During a
Ramp-Hold firing, press the
. will appear. Press
. The current segment
ramp or hold number will ap
-
pear. To skip, press
again. Page 10
During a
Ramp-Hold firing, press
repeatedly until ap
-
pears. Press .Eachtime
you press the ,the
hold time for the current seg
-
ment will increase by 5 minutes.
Then press .
Page 10
During a Ramp-Hold firing,
press repeatedly until
appears. Press .
Use the arrow keys to change
the target temperature for the
current segment. Then press
.Page10
During a fir
-
ing, press repeatedly
until appears. Press
. Use the arrow keys to
change the alarm temperature.
Press .Tosilencethe
alarm, press any key. Page 10
At the display,
press . will ap
-
pear. Use arrow keys to adjust
the controller to fire hotter or
cooler. Press to return to
.Page13
*These features are new with the Sentry Xpress 4.0. If your controller does
not have these features, it is an earlier controller.

Other manuals for Orton Sentry Xpress 4.0

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Orton Sentry Xpress 4.0 and is the answer not in the manual?

Orton Sentry Xpress 4.0 Specifications

General IconGeneral
BrandOrton
ModelSentry Xpress 4.0
CategoryTemperature Controller
LanguageEnglish

Related product manuals