Sentry 2.0
Digital Temperature Controller
Complete Operating Instructions
See pages 28-29 for instructions on upgrading your DTC
100, 600, 800 or 1000 series board to the Sentry.
Delay (pg 6)
From IdLE, press 3.
Enter time in hours:minutes.
Delays the start of firing.
Program Review (pg 6)
From IdLE or during
firing, press 6.
Shows the program that is
loaded in memory and ready to
fire, or the one that is firing.
Cone Table & Skip
Segment (pg 7)
From IdLE or during
firing, press 9.
From IdLE, shows tempera
-
ture for the cone you enter.
While Firing: In Ramp-Hold,
skips to the next ramp. In
Cone-Fire, skips out of
Pre-Heat or Hold.
Stop/Back (pg 7)
Press during firing or
programming.
Stops a firing. In Options,
takes you back to IdLE.
During programming,
takes you back one step
each time key is pressed.
Options (pg 17 - 21)
From IdLE, press 0. Press
Enter for option displayed.
Cone-Fire Options
SPd Speed Change the speed
of a Cone-Fire program beyond
the Fast, Medium, or Slow.
OFST Cone Offset Adjust con
-
troller to a witness cone.
FAN Vent Fan Selects when
the vent fan will operate. (Special
option not on all kilns.)
Standard Options
TCOS Thermocouple Offset
Calibrate the thermocouple
temperature.
CHG- Select °F or °C.
TC Thermocouple Type Se
-
lect Type K, S or R.
AOP AOP Outlet Select vent
fan or alarm. This is a special op
-
tion not on all kilns.
Alarm (pg 6)
From IdLE or during
firing, press 7.
Enter a temperature. When
alarm sounds during firing,
press Enter.
Present Status (pg 6)
Press 5 during firing.
Shows the segment that is
currently firing. Works in
both Ramp-Hold and
Cone-Fire.
Cone-Fire (pg 8-11)
From IdLE, press 1.
Available only on ceramic
kilns. Fires to a pyrometric
cone. Enter cone, speed,
pre-heat, hold, and slow cool.
Add Time (pg 6)
During firing, press 2.
Each additional key press
adds five minutes to a hold.
It works in both Ramp-Hold
and Cone-Fire.
Ramp-Hold (pg 12-15)
From IdLE, press 4.
Select stored program (1 - 4).
Enter rate, temperature, and
hold for each segment.
Enter/Start (pg 7)
Press Enter/Start after each
step in programming a firing.
Press Enter/Start once to be
-
gin the firing.
Id Computer ID Select identi
-
fication number for output to a
computer.
TEdE Temperature Deviation
Set temperature sensitivity of er
-
ror codes.
SFTY Maximum temp.
ELEC Electronics Temp.
Check board for overheating.
LOCK Program Lock Make a
program tamper-proof.
CFG Configuration Code
For technicians.
SOFT Software Version
For technicians.
TEST Element Test Diagnos
-
tics tool for checking elements.
RST Reset Removes cone
and thermocouple offsets, etc.
Multiple Zone Options
DIFF Difference Largest
temperature difference be
-
tween any two zones.
CAdJ Center Adjustment
Change center heat of some
two-zone kilns.
T123 Zone Tempera
-
tures Shows temperature of
each zone.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Orton Sentry 2.0 and is the answer not in the manual?

Summary

Safety Guidelines and Precautions

Basic Controller Operation and Indicators

Controller Keypad Functions Overview

Ramp Hold, Present Status, Review, and Alarm Keys

Using keys for programming, status checks, review, and alarms.

Advanced Key Controls and Navigation

Enter;Start, Options, and Stop;Back Key Functions

Key functions for starting, options, and navigation.

Cone-Fire Mode: Introduction

Cone-Fire Firing Schedule Categories

Key Cone-Fire Operational Features

Pre-Heat Functionality (PRHT)

Using Pre-Heat to dry greenware before firing.

Cone-Fire Programming Steps

Hold Function in Cone-Fire

Troubleshooting Early Kiln Shut-Off

Ramp-Hold Segment Fundamentals

Definition and Components of a Segment

Explaining the ramp and hold components of a segment.

Ramp-Hold Programming Guide

User Program Creation and Storage

Executing Stored Ramp-Hold Programs

Ramp-Hold Segment Parameter Configuration

Specific Ramp-Hold Firing Examples

Ramp-Hold Operational Considerations

Multiple Zone Kiln Operation

Viewing and Analyzing Zone Temperatures

Accessing and interpreting zone temperatures and differences.

Controller Options Menu

Adjusting Cone-Fire Speed (SPd)

Fine-tuning firing speed for Cone-Fire.

Calibrating Cone Offset (OFST)

Adjusting shut-off point for specific cone ranges.

Using Cone Offset for Calibration

Interpreting Cone Bending Results

General Controller Options

Thermocouple Offset Calibration (TCOS)

Calibrating the controller's temperature readings.

Thermocouple Offset Calibration Methods

Calibration Using a Digital Pyrometer

Using a pyrometer for accurate offset calibration.

Setting Thermocouple Offset Values

Entering offset values for temperature correction.

Selecting the Correct Thermocouple Type (TC)

Temperature Deviation Sensitivity (TEDE)

Program Lock for Security

Element and Thermocouple Testing

Multiple Zone Specific Options

Zone Temperature Viewing (T123)

Displaying temperatures for each individual zone.

Understanding Sentry Error Messages

Terminating Error Types

Errors that cause the firing to halt.

Sentry Power Failure Handling

PLOG Diagnostic Error Codes

Uneven Multiple Zone Temperatures (TCdE)

Appendix C: Upgrading Instructions

DTC to Sentry Controller Upgrade Process

Step-by-step guide for upgrading older controllers.

Wiring the Sentry Controller

Appendix E: Ramp-Hold Shorthand Programming

Appendix F: Cone-Fire Shorthand Programming

Orton Sentry 2.0 Specifications

General IconGeneral
BrandOrton
ModelSentry 2.0
CategoryTemperature Controller
Control TypePID
Input TypeThermocouple
Output TypeRelay
DisplayLED

Related product manuals