EasyManua.ls Logo

Orton Sentry 2.0 - Default Chapter; Table of Contents

Default Icon
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
Contents
Basic Pointers . . . . . . . . . . 4
Which Instructions
Apply to Your Controller . . . . . . . . . . 4
Room Temperature and Humidity. . . 4
Thunder Storms and Power Surges . 4
Display Lights . . . . . . . . . . . . . . . . . . 5
How to Get IdLE to Display . . . . . . . . 5
Firing Completion Message . . . . . . . 5
Repeat Firings . . . . . . . . . . . . . . . . . . 5
Thermocouple Inspection . . . . . . . . . 5
The “LId” Display. . . . . . . . . . . . . . . . 5
The Keys . . . . . . . . . . . . . . . 6
Correcting Entries . . . . . . . . . . . . . . . 6
1 / Cone Fire . . . . . . . . . . . . . . . . . . . 6
2 / Add Time . . . . . . . . . . . . . . . . . . . 6
3 / Delay. . . . . . . . . . . . . . . . . . . . . . . 6
4 / Ramp Hold . . . . . . . . . . . . . . . . . . 6
5 / Present Status . . . . . . . . . . . . . . . 6
6 / Program Review . . . . . . . . . . . . . . 6
7 / Alarm. . . . . . . . . . . . . . . . . . . . . . . 6
9 / Cone Numbers & Skip Segment . 7
Enter/Start . . . . . . . . . . . . . . . . . . . . . 7
The Options Key . . . . . . . . . . . . . . . . 7
The Stop/Back Key . . . . . . . . . . . . . . 7
Cone-Fire . . . . . . . . . . . . . . 8
Standard Schedules
Low Fire Cones 022 - 011. . . . . . . . 9
Middle Fire Cones 010 - 01 . . . . . . 9
High Fire Cones 1 - 10 . . . . . . . . . . 9
Speed (SPd) . . . . . . . . . . . . . . . . . . . 9
Pre-Heat (PRHT) . . . . . . . . . . . . . . . . 9
Hold (HOLd) . . . . . . . . . . . . . . . . . . 10
Cone-Fire Programming . . . . . . . . . 10
Slow Cooling (COOL) . . . . . . . . . . . 11
When the Kiln Shuts Off Too Soon . 11
For Kilns with AOP Outlet . . . . . . . . 11
Ramp-Hold . . . . . . . . . . . . 12
Definition of a Segment . . . . . . . . . . 12
Ramp-Hold Programming . . . . . . . . 13
User Programs (USER) . . . . . . . . . . 13
Firing a Stored User Program . . . . . 14
Rate . . . . . . . . . . . . . . . . . . . . . . . . . 14
Hold (HOLd) . . . . . . . . . . . . . . . . . . 14
AOP Fan. . . . . . . . . . . . . . . . . . . . . . 14
Segments for Controlled Cooling . . 14
Sample Firing Schedules . . . . . . . . 14
Cone-Fire Program Fired in
Ramp-Hold . . . . . . . . . . . . . . . . . . 14
Sculptured Stoneware Bisque
Firing Schedule, Cone 04. . . . . . . 14
Glass Fusing Firing Schedule . . . 15
Glass Slumping Firing Schedule . 15
Starting a Firing in a Hot Kiln. . . . . . 15
When the Kiln Shuts Off Too Soon . 15
Multiple Zone Kilns . . . . . 16
An Overview of Multiple
Zone Firing. . . . . . . . . . . . . . . . . . . . 16
Viewing Zone Temperatures . . . . . . 16
Two Zone Kilns: Adjust Heat in
Center Section (CAdJ). . . . . . . . . . . 16
Thermocouple Failure
In a Multiple Zone Kiln . . . . . . . . . . . 16
Power Output Lights . . . . . . . . . . . . 16
Testing Multiple Zone Elements . . . 16
Options: Cone-Fire. . . . . . 17
Cone-Fire Speed (Spd) . . . . . . . . . . 17
Cone Offset (OFST) . . . . . . . . . . . . . 17
Interpreting Cone Bending . . . . . . 18
When Cone Temperature
Is Off More Than 20°F/11°C . . . . . 18
Fan (FAN) . . . . . . . . . . . . . . . . . . . . 18
Options: General . . . . . . . 18
Thermocouple Offset (TCOS) . . . . . 18
Thermocouple Offset for
Ceramic Firings. . . . . . . . . . . . . . . 18
Calibrating Thermocouple Offset
With a Digital Pyrometer. . . . . . . . 19
Setting Thermocouple Offset . . . . 19
Multiple Zone
Thermocouple Offset . . . . . . . . . . 19
Selecting °F or °C (CHG-) . . . . . . . . 19
°F/°C Temperature
Conversion Formula . . . . . . . . . . . 19
Thermocouple Type (TC) . . . . . . . . 19
AOP Outlet (AOP) . . . . . . . . . . . . . . 20
Computer ID (ID) . . . . . . . . . . . . . . . 20
Temperature Deviation (TEDE) . . . . 20
Maximum Temperature (SFTY) . . . . 20
Electronics Temperture (ELEC). . . . 20
Program Lock (LOCK) . . . . . . . . . . . 20
Configuration Code (CFG) . . . . . . . 21
Software Version (SOFT). . . . . . . . . 21
Element Test (TEST) . . . . . . . . . . . . 21
Reset (RST) . . . . . . . . . . . . . . . . . . . 21
Options: Multiple Zone . . 21
Zone Temperature
Difference (DIFF) . . . . . . . . . . . . . . . 21
Two Zone Kilns: Adjust Heat in
Center Section (CAdJ). . . . . . . . . . . 21
Zone Temperatures (T123) . . . . . . . 21
Error Messages . . . . . . . . 22
FTC / Failed to Cool. . . . . . . . . . . . . 22
FTH / Failed to Heat. . . . . . . . . . . . . 22
LTdE / Low Temperature
Deviation . . . . . . . . . . . . . . . . . . . . . 22
PF / Power Failure . . . . . . . . . . . . . . 22
BAdP / Bad Programming . . . . . . . . 22
ETH / Electronics Too Hot. . . . . . . . 22
FAIL / Thermocouple Failure . . . . . . 22
FTL / Firing Too Long . . . . . . . . . . . 22
HTdE / High Temperature
Deviation . . . . . . . . . . . . . . . . . . . . . 22
PF 2 / Power Failure . . . . . . . . . . . . 22
PF 3 / Power Failure . . . . . . . . . . . . 22
How the Sentry
Handles Power Failures. . . . . . . . . . 23
Using Ceramic Witness Cones
After an Extended Power Failure . 23
PLOG Error Codes. . . . . . . . . . . . . . 23
TCdE / Uneven Multiple
Zone Temperatures . . . . . . . . . . . . . 23
TCR / Thermocouple
Leads Reversed. . . . . . . . . . . . . . . . 23
Appendix A
Display Messages . . . . . . . . . . . . . . 24
Appendix B
Standard Cone-Fire Schedules. . . . 26
Appendix C
Upgrading the DTC 100, 600, 800 &
1000 to the Sentry . . . . . . . . . . . . . . 28
Appendix D
Orton Pyrometric Cone
Temperature Equivalents . . . . . . . . 30
Appendix E
Ramp-Hold Shorthand . . . . . . . . . . 31
Appendix F
Cone-Fire Shorthand . . . . . . . . . . . . 32

Table of Contents

Related product manuals