The Sentry Xpress 4.0 micro processor is manufactured by the
Orton Ceramic Foundation and displays the CE mark.
Hr./Min.
When Lit
HIGHER
°C
°F
When Off
When Lit
START/
STOP
LOWER
Program
Review
Run
MICRO PROCESSOR
TM
SENTRYXpress
4.0
Enter
Program
Skip Seg.
Add Hold
Change Temp.
T/C Offset
Alarm
Delay
Review
1
START/STOP Key
Starts and stops a firing.
Press after each
programming step. It works like the
Enter key on a computer.
Up Arrow Key
From
press .Press
to select Single-Speed or
Ramp-Hold. Pages 6, 8
During a
Ramp-Hold firing, press the
. will appear. Press
. The current segment ramp
or hold number will appear. To
skip, press again. Page 8
During a
Ramp-Hold firing, press
repeatedly until appears.
Press .Eachtimeyoupress
the , the hold time for the
current segment will increase by 5
minutes. Then press .
Page 8
During a Ramp-Hold firing,
press repeatedly until
appears. Press .Use
the arrow keys to change the target
temperature for the current seg
-
ment. Then press .Page9
During a firing,
press repeatedly until
appears. Press .Use
the arrow keys to change the alarm
temperature. Press .Tosi
-
lence the alarm, press any key.
Page 9
At the display, press
. will appear. Use ar
-
row keys to adjust the controller to
fire hotter or cooler. Press
to return to .Page12
Down Arrow Key
From press
.Thepro
-
gram you have selected
will appear one step at a
time. When ap
-
pears, press .
Page 4
From
press .
Enter delay time. Press
twice. Page 4
During firing, press
. The program you
entered will appear one
step at a time. Page 4
Light is
on during pro
-
gramming.
Light is
on during pro
-
gram review.
Light
blinks during firing.
Temperature Display
Temperature
display is in °F.
Tem
-
perature display is in °C.
Seepage12forinstructionson
selecting °F or °C.
Time Display
:Sepa-
rates hours from minutes. Ex-
ample: Display shown above
is 1 hour and 30 minutes.
°F
°C
°C Display Dot
Sentry Xpress
Digital Temperature Controller
Single-Speed / Ramp-Hold Version
IM-221/7-11
Indicator
Lights
*These features are new with the Sentry Xpress 4.0. This manual, neverthe
-
less, is backward compatible with earlier controllers.

Other manuals for Orton Sentry Xpress 4.0

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Orton Sentry Xpress 4.0 and is the answer not in the manual?

Orton Sentry Xpress 4.0 Specifications

General IconGeneral
BrandOrton
ModelSentry Xpress 4.0
CategoryTemperature Controller
LanguageEnglish

Related product manuals