EXTENDED OPERATING INSTRUCTIONS
FOR THE AVALANCHE TRANSCEIVER ORTOVOX S1
TRANSMISSION AND AUTOMATIC SAFETY SWITCHBACK
FOR TRANSMIT (MOTION SENSOR):
If the S1 is motionless for 90 seconds while open then the transmis-
sion mode will be automatically activated from every function depen-
ding on the setting selected. In the event of a subsequent avalanche
the S1 switches to transmission after 90 seconds (factory setting;
time can be set at 30, 60 and 120 seconds via thesettings” menu).
SIGNAL SEARCH (= search for first signal):
Move through the presumed search area in stripes with a width of 50 m
while ensuring 25 m distance from the side edge of the avalanche.
Several searchers:
The distance between
searchers is 50 m.