Method of procedure
1. Place the S1 on a flat, horizontal surface
without metal parts (display faces upwards).
2. Select the "Settings" symbol from the "MENU".
3. Select the calibration symbol.
4. Press the "OK button", wait for approximately
2 seconds until calibration starts.
5. Turn the S1 in a horizontal position slowly
(5 - 10 seconds) once around its own axis (360°).
Wait for beep.
COMPASS CALIBRATION
To display the direction as fast as possible the ORTOVOX S1 uses an elec-
tronic compass. We recommend "calibrating" the compass before the
start of every winter season and after changing the battery. Any compass
discrepancy occurring is compensated by calibration. For calibration purpo-
ses, use only a flat surface without metal parts. The distance from elec-
tricity conducting leads or metal parts, particularly magnetic objects (loud-
speakers) should be at least 2m.
59
ENGLISH