EasyManua.ls Logo

OSAKA VACUUM TC223 User Manual

Default Icon
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
OSAKA VACUUM, LTD.
Document No. : ND00338-R06
INSTRUCTION MANUAL
POWER SUPPLY
For the pump
MODEL: TC163H
TC223
TC523H
TC203
TC353
TC1104
IMPORTANT
Read rule carefully for safe installation, operation and instruction.
Please keep this instruction manual by your side.
OSAKA VACUUM, LTD.

Other manuals for OSAKA VACUUM TC223

Question and Answer IconNeed help?

Do you have a question about the OSAKA VACUUM TC223 and is the answer not in the manual?

OSAKA VACUUM TC223 Specifications

General IconGeneral
BrandOSAKA VACUUM
ModelTC223
CategoryPower Supply
LanguageEnglish

Summary

Introduction to the Manual

Manual Purpose and Recommendation

Read this manual carefully for understanding functions and correct handling.

Warranty Details

Product Quality Warranty

Company warrants power supply quality per standard warranty conditions.

Safety Precautions

General Safety and Handling

Covers input power, pump combinations, fan mode, earth, cables, and disassembly.

Environmental and Electrical Hazards

Avoids electric shock, extreme environments, dust, gas, fields, vibration, and space issues.

Opening the Crate

Contents and Condition Check

Verify power supply and attachments are undamaged and complete upon receipt.

Product Features

High-Frequency Inverter Operation

Controls motor current and output voltage for efficient pump operation and quick starts.

Product Specifications

Specifications Table

Detailed specifications including input/output voltage, frequency, power, and ratings.

Control Panel and Display

Buttons and Input Switch

Details on input voltage switch, function, start, and stop/reset buttons.

Display Indications

Explains how operation status, speed, time, and modes are displayed.

Maintenance Mode

Entering and Navigating Maintenance Mode

Procedure to enter MAINTENANCE MODE and navigate parameters using function buttons.

Maintenance Mode Functions (Part 1)

No-load Test and Operation Time Reset

Configuring no-load test and resetting total operation time.

Protection Signal and Fan Detection

Managing protection signals and fan disconnection detection settings.

Maintenance Mode Functions (Part 2)

Operation Mode Selection

Selecting between LOCAL, REMOTE, and SERIAL COMMUNICATION modes.

Maintenance Mode Functions (Part 3)

CRC Code and Error Log

Using CRC code and viewing/clearing error (alarm) logs.

Protective Functions

Error Descriptions and Measures (Table 4-1)

Details on acceleration, protection signal, and fan disconnection errors with remedies.

Error Handling and Warnings

Light Load, Motor Cable, and Over-current Errors

Troubleshooting for light load, motor cable, and over-current faults.

Overheat and Input Voltage Issues

Addressing pump/PS overheat and input voltage dropping errors.

System Errors and Warning Functions

Over Frequency, System Errors, and Bearing Warning

Handling over frequency, system errors, and bearing replacement warnings.

Error Reset Procedures

Resetting Over Frequency and System Errors

Procedure to reset over frequency and system errors by power cycling.

Resetting Other Errors

Using the STOP button to reset other types of errors in various operation modes.

Installation and Electrical Connections

Installation Procedures

Guidelines for installing the power supply in a rack or on the floor.

Electrical Connection Guide

Detailed instructions for connecting input power, motor, fan, and remote cables.

Cable and Connector Specifications

Attached Connectors and Cables Table

Details on connector types and cables provided for input power, remote, motor, etc.

Input Power Cable Connection

Steps for connecting the input power cable, including voltage selection.

Wiring and Signal Connections

Motor, Fan, and Remote Cable Connections

Connecting motor, fan cables, and remote cable for control signals.

Remote Connector Signal Definitions

Explanation of signals for START/STOP, protection, acceleration, normal, failure, and brake.

Maintenance and Inspection

Tuning and LCD Contrast Adjustment

Information on tuning and adjusting the display's LCD contrast.

No-load Test Procedure

Steps for performing a no-load test to check power supply functionality.

Other Operations and Disposal

Pump Start/Stop and Power Supply Precautions

Operating the pump via buttons or signals; power supply precautions.

Industrial Waste Disposal

Guidelines for handling the power supply as industrial waste when discarding.

Company Contact Information

Osaka Vacuum Ltd. Offices

Contact details for head office, Tokyo, Seoul, and Shanghai offices.

Osaka Vacuum U.S.A. and Service Centers

Contact information for US branch and global service centers.

Standard Warranty Conditions

Warranty and Indemnification

Details on product warranty, coverage, and user indemnification for damages.

Warranty Exceptions and Governing Law

Exclusions from warranty and the governing law for disputes.