EasyManuals Logo

Osburn 2000 User Manual

Osburn 2000
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
Page 8
Installation and Operation Manual - 2000
ENGLISH
2. General Information
2.1 Performances
Values are as measured per test method, except for the recommended heating area, firebox volume,
maximum burn time and maximum heat output.
Model 2000 (OB02015)
Fuel Type Dry Cordwood
Recommended heating area (sq. ft.
.
)
1
500 to 2,100 ft
2
(47 to 195 m
2
)
Nominal firebox volume 2.4 ft
3
(0.068 m
3
)
Maximum burn time
1
8 hours
Maximum heat output (dry cordwood)
2
75,000 BTU/h (22.0 kW)
Overall heat output rate (min. to max.)
2 3
14,800 BTU/h to 28,600 BTU/h
(4.34 kW to 8.38 kW)
Average overall efficiency
3
Dry cordwood
69 % (HHV)
4
74 % (LHV)
5
Optimum efficiency
6
77 %
Average particulate emissions rate
7
1.54 g/h (EPA / CSA B415.1-10)
8
Average CO
9
89.4 g/h
1
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors, climate, fuel type, feed
rate, fuel level, and other variables. The recommended heated area for a given appliance is dened by the manufacturer as its capacity to maintain a
minimum acceptable temperature considering that the space conguration and the presence of heat distribution systems have a signicant impact
in making heat circulation optimum.
2
The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft
3
and 20 lb/ft
3
. Other performances are based on
a fuel load prescribed by the standard. The specied loading density varies between 7 lb/ft³ and 12 lb/ft
3
. The moisture content is between 19%
and 25%.
3
As measured per CSA B415.1-10 stack loss method.
4
Higher Heating Value of the fuel.
5
Lower Heating Value of the fuel.
6
Optimum overall efciency at a specic burn rate (LHV).
7
This appliance is ofcially tested and certied by an independent agency.
8
Tested and certied in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and Draft ASTM WK47329-14.
9
Carbon monoxide.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Osburn 2000 and is the answer not in the manual?

Osburn 2000 Specifications

General IconGeneral
Firebox Volume2.4 cu. ft.
Chimney Diameter6 inches
Weight400 lbs
EPA CertifiedYes
MaterialSteel
WarrantyLimited Lifetime
Efficiency77%
Maximum Log Length20 inches
Burn Time8 - 10 hours