PRODUCT INFORMATION
PULL-FORCE MEASUREMENT SYSTEM POWER-CHECK 2
2.4 TECHNICAL DATA
Measuring range see order numbers → 2.5 )
Accuracy class (basic unit) 1 % of maximal value
Temperature range +15 °C to + 35 °C
Force limit: 130 % of maximal value
Break force 200 % of maximal value
Measuring system Straingage
Charging process via USB interface
Weight max. 1,5 kg
Battery lifetime Automatic mode:
2 months / 600 measurings
Permanent measuring mode:
1 week (measuring interval: 5 seconds)
* Deviation of adapter is not included
2.5 ORDER NUMBERS
2.5.1 Measurement system without transmitter function
Size Indicating
range
[kN]
Measuring range
[kN]
→ # 5.5 23
possible Interface AVersion without
transmitter function
set * order-no.
item no. of the
basic unit;
not separately
orderable
- 5 kN 0,1 - 5 0,5 - 5 SK 10 ....25
HSK E20, E25
95.103.134.9.2
95.103.082.2.2
- 20 kN 0,5 - 20 2,5 - 20 SK 30, SK 40
HSK A32, A40, A50
95.103.135.9.2
95.103.083.2.2
- 75 kN 2 - 75 10 - 75 SK 50
HSK A63, A80, A100
95.103.136.9.2
95.103.084.2.2
- 200
kN **
5 - 200 25 - 200 SK 60
HSK A125, A160
95.103.137.9.2
95.103.085.2.2
* the set consists of:
Pull-force measurement system (Base unit), tool, PC software with driver CD,
USB connection cable, Product Information, Quick guide
POWER-CHECK-2_PE_2015-09
Subject to modification due to technical advance! // 10