PRODUCT INFORMATION
PULL-FORCE MEASUREMENT SYSTEM POWER-CHECK 2
5.2 AUTOMATIC OPERATION
In automatic operation, the measured pull-force is stored internally and can be logged with an adequate
reading device (USB interface).
The wireless version sends the measuring value to the receiving device.
During automatic operation, application from a tool magazine is possible.
Spindle rotation with the measuring device is not allowed!
Activate
press briefly
The battery charging condition is briefly display (bar display 0 - 100%); the
device is operational thereafter
change to
automatic
operation
push 1 second
LED flashes
on
The measurement tool switches from standby to operation automatically as
soon as it is moved. It checks for a measurable force and stores it if
applicable. If there is no measurable force applied, the device switches
back to standby after a pre-defined time.
Many thousand measurements can be stored and logged with an adequate
reading device (USB interface).
change to
manual mode
push 1 second
LED
on
and
manual
light up
Ausschalten
push 1 second
Possible only in manual mode!
POWER-CHECK-2_PE_2015-09
Subject to modification due to technical advance! // 20