PRODUCT INFORMATION
PULL-FORCE MEASUREMENT SYSTEM POWER-CHECK 2
5.3 CONTINUOUS MEASURING MODE
In continuous measuring mode, it is possible to perform a defined number of measurements with a
defined time interval.
Factory setup is 10 measurements with a 0.5 second time interval:
The total measuring series lasts (10-1) x 0.5 = 4.5 seconds.
The number and time interval may be adjusted using the Power-Check 2 - PC software (USB interface).
The wireless version sends the measuring value to the receiving device.
Activate
push
clear
until - - - is displayed
Recording of the measuring series starts immediately.
Manual operation is subsequently activated.
POWER-CHECK-2_PE_2015-09
Subject to modification due to technical advance! // 21
clear