PRODUCT INFORMATION
PULL-FORCE MEASUREMENT SYSTEM POWER-CHECK 2
The following values can be adjusted:
Identification number ID
Id
and shortly thereafter the identification number are displayed [0 - 31].
An identification number may be entered here, e.g. when various
clamping systems are measured.
Motion sensor threshold
value
Int (for interrupt) is briefly displayed; shortly thereafter followed by a
value between 0 and 255.
This value indicates the motion sensor threshold value:
small value indicates that low accelerations are needed to trigger; high
value indicates that high accelerations are required; ; our
recommendation: ~ 40.
Change threshold values: see above
Measuring duration in
automatic mode
dur (duration) is briefly display; shortly thereafter followed by a value.
This value indicates the duration during which the measured values are
recorded in automatic mode. The maximum value of these measured
values will then be logged.
Example: ~ 10 (approx. 5 seconds)
Display brightness
bri (for brightness) is briefly displayed; shortly thereafter followed by a
value between 0 and 255.
This value indicates the screen brightness.
a small value indicates a dark screen (low power consumption); high
value - bright (high power consumption);
our recommendation: ~ 130 - 200
Press
clear
again to return to the
id
loop. (loop).
Exit configuration menu
manual
auto
For exiting the configuration menu:
push mode until the display changes to manual mode
POWER-CHECK-2_PE_2015-09