EasyManua.ls Logo

OXO GOOD GPIPS CHEF'S PRECISION - User Manual

OXO GOOD GPIPS CHEF'S PRECISION
6 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
CHEF’S PRECISION
THERMOCOUPLE
THERMOMETER
www.oxo.com
PCKG V1

Questions and Answers

Summary

How to Use the Thermocouple Thermometer

Adjusting the Probe Angle

Rotate the probe to the desired angle, up to 225 degrees, for versatile use.

Using the Probe Notch

Utilize the notch on the back of the thermometer to easily grab the probe.

Automatic Activation and Insertion

The thermometer turns on when the probe rotates. Insert probe 1/8" (3 mm) into thickest food section.

Cleaning the Thermocouple Thermometer

Body and Probe Cleaning

Wipe the probe after each use and the thermometer body regularly with a damp cloth.

Rinsing with Water

The IP66 rating allows rinsing the thermometer in water for cleaning; do not immerse.

Changing Thermometer Preferences

Accessing Battery Compartment

Loosen the battery door screw with a Phillips screwdriver to access the compartment.

Adjusting Temperature Units and Resolution

Use switches inside the compartment to change between °F/°C or adjust decimal resolution.

Thermometer Specifications

Measurement and Operating Ranges

Covers measurement range from -58 to +572°F (-50 to 300°C) and operating range from 32 to 122°F (0 to 50°C).

Accuracy and Water Resistance

Details accuracy specifications and IP66 water resistance rating.

Troubleshooting Thermometer Errors

Automatic On;Off Behavior

Thermometer enters sleep mode after 3 minutes and turns off after 10 minutes of inactivity.

Error E-2: Ambient Temperature Changes

Indicates exposure to rapid ambient temperature changes; reset by removing and reinserting batteries.

Error Er3: Out of Functional Range

Shows when ambient temperature is outside 0°C-50°C (32°F-122°F); requires reset and stabilization.

Error Eг: Needs Reset

Indicates the thermometer needs to be reset; turn off, remove batteries, wait, and reinsert.

Error H, Lo: Out of Measurement Range

Displayed when measured temperature is outside the measurement range; auto-corrects when back in range.

Product Warranty and Certifications

Two-Year Limited Warranty

Covers manufacturing defects for two years in the US and Canada; excludes misuse and unauthorized repairs.

NSF Certification

Approved by NSF for quality and food safety standards, including Certificate of Compliance (COCO) and EMC standards.

OXO GOOD GPIPS CHEF'S PRECISION Specifications

General IconGeneral
Accuracy±1.8°F/1°C between -4 to 302°F/-20 to 150°C
DisplayDigital
MagnetYes
Temperature Range-40 to 572°F / -40 to 300°C
FeaturesTimer
Probe Length4.5 inches
Power SourceBattery
Auto-OffYes