EasyManua.ls Logo

Ozito IGP-2500 - OPERATION; Fuel Management and Refuelling; Starting Procedures

Ozito IGP-2500
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
2. FUEL 3. STARTING & STOPPING
OPERATION
Refuelling the Generator
Fuel Consumption
Preparing to Start
2. Set the engine switch to
ON.
1. Setthefueltaptothe“ON”
position as shown.
3. Adjust the choke to suit the current
conditions.
COLD START: Iftheweatheriscold,
pushthechokeallthewaytotheleft
intothe“ON”position.
WARM START: Iftheweatheriswarm
or the generator has recently been
used,pushthechokeallthewayto
therightintothe“OFF”position.
OFF
ON
1. Switcho󰀨engineby
moving the engine switch
to the OFF position.
2. Removethefuelcapby
rotating in a anti-clockwise
direction.
3. Addfueltothetank(91RON
Unleaded Petrol). Do not
overllthefueltank,check
thefuelgaugeonthefuel
tank. Do not use ethanol
blendedfuels.Fueltank
capacity is 5L.
E
F
4. Afterrefuelling,makesurethefuelcapisclosedproperlyand
securely.
WARNING! BE CAREFUL NOT TO SPILL FUEL WHEN
REFUELLING. SPILLED FUEL OR FUEL VAPOUR MAY
IGNITE. IF ANY FUEL IS SPILLED, MAKE SURE THE AREA
IS DRY BEFORE STARTING THE ENGINE.
WARNING! KEEP AWAY FROM CIGARETTES, SMOKE AND
SPARKS WHEN REFUELLING THE GENERATOR. ALWAYS
REFUEL IN A WELL-VENTILATED LOCATION.
Beforestartingtheengine,disconnectallappliancesfromthe
generator.
OFF
ON
CHOKE LEVER
Starting the Engine
Beforestartingtheengine,disconnectallappliancesfromthe
generator.
1. Follow steps 1 to 3 in the “Preparing to Start” section above.
2. Hold the generator steady
with one hand. With the
otherhand,pullslightlyon
the recoil starter until you
feelresistanceandthen
pullhardandswiftly.Do
not let the recoil starter
retractbyitself,guideit
back by hand.
3. Oncestartedpushthechokeallthewaytotherightintothe“OFF”
position.
Note:Youmayneedtopullontherecoilstarterafewtimesuntilthe
generator starts.
WARNING! PETROL IS VERY FLAMMABLE. DO NOT
SMOKE OR CAUSE ANY SPARKS OR FLAMES NEAR
FUEL. MAKE SURE THAT YOU STOP THE ENGINE
AND ALLOW IT TO COOL BEFORE REFUELLING THE
GENERATOR. SELECT AN OPEN OUTDOOR AREA FOR
FUELLING AND MOVE AT LEAST 3M AWAY FROM THE
FUELLING POINT BEFORE STARTING THE ENGINE.
Load Fuel Consumption Run Time (full tank)
2200W(fullload) 1500mL/h 3 hours
1100W(halfload) 1026mL/h 4.5 hours

Other manuals for Ozito IGP-2500