42 Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Product Description
43
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Product Description
Split Systems with Hydro-Module / LT Series / H Generation (contd.)
LT series Three-phase (400 V / 50 Hz), heating and cooling
Hydro-module WH-SDC09H3E8 WH-SDC12H9E8 WH-SDC16H9E8
Outdoor unit WH-UD09HE8 WH-UD12HE8 WH-UD16HE8
Set (hydro-module + outdoor unit) KIT-WC09H3E8 KIT-WC12H9E8 KIT-WC16H9E8
Model B6 B6 B6
Heatingcapacityat+7°C(A7/W35) kW 9.00 12.00 16.00
COPat+7°C(A7/W35) 4.84 4.14 4.28
Heatingcapacityat+2°C(A2/W35) kW 9.00 11.40 13.00
COPat+2°C(A2/W35) 3.59 3.44 3.28
Heating capacity at -7 °C (A–7/W35) kW 9.00 10.00 11.40
COP at -7 °C (A–7/W35) 2.85 2.73 2.68
Cooling capacity at 35 °C (A35/W7) kW 7.00 10.00 12.20
EER at 35 °C (A35/W7) 3.17 2.81 2.56
Energyefciencyclass
1
at 35 / 55 °C
i / i i / i i / i
Hydro-module
Sound pressure level Heating / Cooling dB(A) 28 / 28 28 / 28 28 / 28
Dimensions HxLxW mm 892 x 500 x 340 892 x 500 x 340 892 x 500 x 340
Weight kg 44 44 44
Water-side connection mm 28 28 28
Highefciencypump
Rotation speed stages Variable Variable Variable
Powerconsumption(min./max.)
W 32 / 102 34 / 110 30 / 105
Waterowrate(A7/W35) l/min 25.8 34.4 45,9
Power of E-heating element kW 3 3 3
Power consumption Heating / Cooling kW 1.86/2.21 2.53/3.51 3.07/4.36
Operating and start up current Heating / Cooling A 2.8/3.4 3.8/5.3 4.7/6.5
Max.powerconsumptiononnetworkconnection1/2 A 11.8/13.0 8.8/13.0 9.4/13.0
Recommended fuse for network connection 1 / 2 A 15 / 30 15 / 30 15 / 30
Recommended cable cross section for network connection 1 / 2
mm² 3x1.5/3x1.5 3x1.5/3x1.5 3x1.5/3x1.5
Outdoor unit
Sound pressure level Heating / Cooling dB(A) 51 / 49 52 / 50 55 / 54
Dimensions HxLxW mm 1,340 x 900 x 320 1,340 x 900 x 320 1,340 x 900 x 320
Weight kg 108 108 108
Linediameter
Fluid line mm (inches) 9.52(3/8) 9.52(3/8) 9.52(3/8)
Gasline mm (inches) 15.88(5/8) 15.88(5/8) 15.88(5/8)
Pre-lledrefrigerant(R410A)/CO
2
-equivalent kg / t CO
2
-Equ. 2.55/5.324 2.55/5.324 2.55/5.324
Connection distance m 3 – 30 3 – 30 3 – 30
Nominal connection distance m 7 7 7
Pre-lledconnectiondistance m 10 10 10
Additionalcoolantll-upquantity(R410A) g/m 50 50 50
Max.heightdifferenceIU/OU m 20 20 20
Operating range Outside temperature (H / K) °C -20 to 35 / 16 to 43 -20 to 35 / 16 to 43 -20 to 35 / 16 to 43
Water outlet temperature (H / K)
°C 25 to 55 / 5 to 20 25 to 55 / 5 to 20 25 to 55 / 5 to 20
The COP details relate to 230 V in conformance with the EC Directives 2003/32/EC. Power details in conformance with EN 14511.
The information about the energy efciency classes is based on the ofcial ErP specications (EU Ordinance No. 811/2013, EN 14511 and EN 14825) for heat pumps, which have been
in force since 26. September 2015. The efciency classes marked with an asterisk (*) correspond to the new A+++ class to be introduced starting in September 2019. Other ErP relevant
information is included in the respective product data sheets.
Authorised Service Partners or installation companies can activate the cooling function via a special setting.
1 Energy efciency class scale from A++ to G.
Split systems with hydro-module / LT series / H Generation
LT series Single-phase (230 V / 50 Hz), Heating and Cooling
Hydro-module WH-SDC03H3E5-1 WH-SDC05H3E5-1 WH-SDC07H3E5-1 WH-SDC09H3E5-1 WH-SDC12H6E5 WH-SDC16H6E5
Outdoor unit WH-UD03HE5-1 WH-UD05HE5-1 WH-UD07HE5-1 WH-UD09HE5-1 WH-UD12HE5 WH-UD16HE5
Set (hydro-module + outdoor unit) KIT-WC03H3E5-1 KIT-WC05H3E5-1 KIT-WC07H3E5-1 KIT-WC09H3E5-1 KIT-WC12H6E5 KIT-WC16H6E5
Model B4 B4 B5 B5 B6 B6
Heatingcapacityat+7°C(A7/W35) kW 3.20 5.00 7.00 9.00 12.0 16.00
COPat+7°C(A7/W35) 5.00 4.63 4.46 4.13 4.74 4.28
Heatingcapacityat+2°C(A2/W35) kW 3.20 4.20 6.55 6.70 11.40 13.00
COPat+2°C(A2/W35) 3.56 3.11 3.34 3.13 3.44 3.28
Heating capacity at -7 °C (A–7/W35) kW 3.20 4.20 5.15 5.90 10.00 11.40
COP at -7 °C (A–7/W35) 2.69 2.59 2.68 2.52 2.73 2.68
Cooling capacity at 35 °C (A35/W7) kW 3.20 4.50 6.00 7.00 10.00 12.20
EER at 35 °C (A35/W7) 3.08 2.69 2.63 2.43 2.81 2.56
Energyefciencyclass
1
at 35 / 55 °C
i*/ i i*/ i i*/ i i*/ i i / i i / i
Compositeenergyefciencyclass
2
at 35 / 55 °C
j / i j / i j / i j / i j / i j / i
Hydro-module
Sound pressure level Heating / Cooling dB(A) 28 / 28 28 / 28 30 / 30 30 / 30 33 / 33 33 / 33
Dimensions HxLxW mm 892 x 500 x 340 892 x 500 x 340 892 x 500 x 340 892 x 500 x 340 892 x 502 x 353 892 x 502 x 353
Weight kg 44 44 44 44 45 46
Water-side connection mm 28 28 28 28 28 28
Highefciencypump
Rotation speed stages Variable Variable Variable Variable Variable Variable
Powerconsumption(min./max.)
W 30 / 100 33 / 106 34 / 114 40 / 120 34 / 110 30 / 105
Waterowrate(A7/W35) l/min 9.2 14.3 20.1 25.8 34.4 45,9
Power of E-heating element kW 3 3 3 3 6 6
Power consumption Heating / Cooling kW 0.64/1.04 1.08/1.67 1.57/2.28 2.18/2.88 2.53/3.56 3.07/4.36
Operating and start up current Heating / Cooling A 3.0/4.8 5.0/7.6 7.2/10.3 10.0/13.0 11.5/16.0 13.9/19.5
Max.powerconsumptiononnetworkconnection1/2 A 11.0/13.0 12.0/13.0 21.0/13.0 22.9/13.0 24.0/26.0 25.0/26.0
Recommended fuse for network connection 1 / 2 A 15 / 30 15 / 30 15 / 30 15 / 30 30 / 30 30 / 30
Recommended cable cross section for network connection 1 / 2
mm² 3x1.5/3x1.5 3x1.5/3x1.5 3x1.5/3x1.5 3x1.5/3x1.5 3x4.0or6.0/3x4.0 3x4.0or6.0/3x4.0
Outdoor unit
Sound pressure level Heating / Cooling dB(A) 47 / 47 48 / 48 50 / 48 51 / 50 52 / 50 55 / 54
Dimensions HxLxW mm 622 x 824 x 298 622 x 824 x 298 795 x 900 x 320 795 x 900 x 320 1,340 x 900 x 320 1,340 x 900 x 320
Weight kg 39 39 66 66 101 101
Linediameter
Fluid line mm (inches) 6.35(1/4) 6.35(1/4) 6.35(1/4) 6.35(1/4) 9.52(3/8) 9.52(3/8)
Gasline mm (inches) 12.7(1/2) 12.7(1/2) 15.88(5/8) 15.88(5/8) 15.88(5/8) 15.88(5/8)
Pre-lledrefrigerant(R410A)/CO
2
-equivalent kg / t CO
2
-Equ. 1.20/2.506 1.20/2.506 1.45/3.028 1.45/3.028 2.55/5.324 2.55/5.324
Connection distance m 3 – 15 3 – 15 3 – 30 3 – 30 3 – 30 3 – 30
Nominal connection distance m 7 7 7 7 7 7
Pre-lledconnectiondistance m 10 10 10 10 10 10
Additionalcoolantll-upquantity(R410A) g/m 20 20 30 30 50 50
Max.heightdifferenceIU/OU m 5 5 20 20 20 20
Operating range Outside temperature (H / K) °C -20 to 35 / 16 to 43 -20 to 35 / 16 to 43 -20 to 35 / 16 to 43 -20 to 35 / 16 to 43 -20 to 35 / 16 to 43 -20 to 35 / 16 to 43
Water outlet temperature (H / K)
°C 20 to 55 / 5 to 20 20 to 55 / 5 to 20 25 to 55 / 5 to 20 25 to 55 / 5 to 20 25 to 55 / 5 to 20 25 to 55 / 5 to 20
The COP details relate to 230 V in conformance with the EC Directives 2003/32/EC. Power details in conformance with EN 14511.
The information about the energy efciency classes is based on the ofcial ErP specications (EU Ordinance No. 811/2013, EN 14511 and EN 14825) for heat pumps, which have been
in force since 26. September 2015. The efciency classes marked with an asterisk (*) correspond to the new A+++ class to be introduced starting in September 2019. Other ErP relevant
information is included in the respective product data sheets.
Authorised Service Partners or installation companies can activate the cooling function via a special setting.
1 Energy efciency class scale from A++ to G.
2 Energy efciency class including controller. Energy efciency class scale from A+++ to D.