108 Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Planning
109
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Planning
For combination hydro-module with the outdoor unit UD07HE5-1 or UD09HE5-1:
Mains supply 1 of this device fulls IEC610000-3-12, provided that the short-cir-
cuit power S
k
at the transfer point of the energy provider is greater than or equal
to 400.00 kW. The installer or operator of the device is, therefore, responsible for
ensuring, in case a consultation with the EVU is needed, that the device is only
connected, if the short-circuit power S
k
is greater than or equal to 400.00 kW.
Mains supply 1 of the device fulls ICE/ EN 61000-3-11 and is to be connected to
a suitable voltage source, which has a current rating ≥100 A per phase. Connect
to the EVU to ensure that the current rating at the transfer point is sufcient for the
device.
Mains supply 2 of this device fulls EN/ IEC 61000-3-11. A suitable voltage source
is to be connected. Its maximum allowed system impedance at the interface is Z
max
= 0.445 Ω. Connect to the EVU to ensure that the mains supply 2 is only connected
to a grid with the maximum of this impedance.
For combination hydro-modules with other outdoor units:
NA
Split systems with hydro-module
Models Mains connection 1 Mains connection 2
Phases Max. current
consumption (A)
Max. power
consumption (kW)
Phases Max. current
consumption (A)
Max. power
consumption (kW)
WH-SDC03H3E5-1 +
WH-UD03HE5-1
1 11.0 2.35 1 13.0 3.0
WH-SDC05H3E5-1 +
WH-UD05HE5-1
1 12.0 2.59 1 13.0 3.0
WH-SDC07H3E5-1 +
WH-UD07HE5-1
1 21.0 4.59 1 13.0 3.0
WH-SDC09H3E5-1 +
WH-UD09HE5-1
1 22.9 5.01 1 13.0 3.0
FI protection switch and mains connections Indoor unit /outdoor unit connection
L N
L N
L
1
N
1
L
1
N
1
1 2
3
1 2
3
3
3
r
L N
L N
L
1
N
1
L
1
N
1
1 2
3
1 2
3
3
3
r
FI protection
switch
Mains connections
L N
L N
L
1
N
1
L
1
N
1
1 2
3
1 2
3
3
3
r
Mains connection 1 Mains connection 2
2
3
1 2 3
1 2 3
L N
L N
L
1
N
1
L
1
N
1
Terminal block strip
Indoor unit / outdoor unit
Connection of indoor unit
and outdoor unit
1 2 3
1 2 3
L N
L N
L
1
N
1
L
1
N
1
1
2
Terminals on indoor unit
Terminals on outdoor unit
Terminals on disconnector of the mains connection
1
2
3
Models Mains connection 1 Mains connection 2
Phases Max. current
consumption (A)
Max. power
consumption (kW)
Phases Max. current
consumption (A)
Max. power
consumption (kW)
WH-SDC12H6E5 +
WH-UD12HE5
1 24.0 5.3 1 26.0 6.0
WH-SDC16H6E5 +
WH-UD16HE5
1 26.0 5.74 1 26.0 6.0
WH-SXC09H3E5 +
WH-UX09HE5
1 25.0 5.4 1 13.0 3.0
WH-SXC12H6E5 +
WH-UX12HE5
1 29.0 6.27 1 26.0 6.0
WH-SHF09F3E5 +
WH-UH09FE5
1 28.5 6.09 1 13.0 3.0
WH-SHF12F6E5 +
WH-UH12FE5
1 29.0 6.2 1 26.0 6.0
FI protection switch and mains connections Indoor unit /outdoor unit connection
1 2 3
2 31
L N
N
L
L
1
N
1
L
1
N
1
A
LN
11
N L
11
1 2 3
2 3
1
L N
N
L
L
1
N
1
L
1
N
1
A
LN
11
N L
11
1 2 3
2 3
1
L N
N
L
L
1
N
1
L
1
N
1
A
LN
11
N L
11
FI protection
switch
Mains connections
Mains connection 1 Mains connection 2
2
3
1 2 3
2 3
1
L N
N
L
L
1
N
1
L
1
N
1
A
LN
11
N L
11
1 2 3
2 3
1
L N
N
L
L
1
N
1
L
1
N
1
A
LN
11
N L
11
Terminal block strip
Indoor unit / outdoor unit
Connection of indoor unit
and outdoor unit
1
2
Terminals on indoor unit
Terminals on outdoor unit
Terminals on disconnector of the mains connection
1
2
3
Models Mains connection 1 Mains connection 2
Phases Max. current
consumption (A)
Max. power
consumption (kW)
Phases Max. current
consumption (A)
Max. power
consumption (kW)
WH-SDC09H3E8 +
WH-UD09HE8
3 11.8 7.94 1 13.0 3.0
WH-SXC09H3E8 +
WH-UX09HE8
3 14.7 9.85 1 13.0 3.0
WH-SQC09H3E8 +
WH-UQ09HE8
3 14.7 9.85 1 13.0 3.0
WH-SHF09F3E8 +
WH-UH09FE8
3 14.5 9.67 1 13.0 3.0
FI protection switch and mains connections Indoor unit /outdoor unit connection
For model WH-SHF09F3E8
1
1
2
2
3
3
4
4
5
5
L
L
N
N
L
A1
L
A2
L
A3
N
L
A1
L
A2
L
A3
N
For model WH-SHF12F9E8
1
1
2
2
3
3
4
4
5
5
L
B1
L
B2
L
B3
N
L
B1
L
B2
L
B3
N
L
A1
L
A2
L
A3
N
L
A1
L
A2
L
A3
N
LN
11
N L
N L
22
POWER SUPPLY 2
LB1 LB2 L B3 N
POWER SUPPLY 1
LA1 LA2 L A3 N
45
A
For model WH-SHF09F3E8
1
1
2
2
3
3
4
4
5
5
L
L
N
N
L
A1
L
A2
L
A3
N
L
A1
L
A2
L
A3
N
For model WH-SHF12F9E8
1
1
2
2
3
3
4
4
5
5
L
B1
L
B2
L
B3
N
L
B1
L
B2
L
B3
N
L
A1
L
A2
L
A3
N
L
A1
L
A2
L
A3
N
LN
11
N L
N L
22
POWER SUPPLY 2
LB1 LB2 L B3 N
POWER SUPPLY 1
LA1 LA2 L A3 N
45
A
For model WH-SHF09F3E8
1
1
2
2
3
3
4
4
5
5
L
L
N
N
L
A1
L
A2
L
A3
N
L
A1
L
A2
L
A3 N
For model WH-SHF12F9E8
1
1
2
2
3
3
4
4
5
5
L
B1
L
B2
L
B3
N
L
B1
L
B2
L
B3
N
L
A1
L
A2
L
A3
N
L
A1
L
A2
L
A3
N
LN
11
N L
N L
22
P OWE R SUPPLY 2
L B1 L B2 LB 3 N
P OWE R SUPPLY 1
L A1 L A2 LA 3 N
A
For model WH-SHF09F3E8
1
1
2
2
3
3
4
4
5
5
L
L
N
N
L
A1
L
A2
L
A3
N
L
A1
L
A2
L
A3 N
For model WH-SHF12F9E8
1
1
2
2
3
3
4
4
5
5
L
B1
L
B2
L
B3
N
L
B1
L
B2
L
B3
N
L
A1
L
A2
L
A3
N
L
A1
L
A2
L
A3
N
LN
11
N L
N L
22
P OWE R SUPPLY 2
L B1 L B2 L B3 N
P OWE R SUPPLY 1
L A1 L A2 L A3 N
A
FI protection
switch
Mains connections
Mains connection 2 Mains connection 1
2
3
For model WH-SHF09F3E8
1
1
2
2
3
3
4
4
5
5
L
L
N
N
L
A1
L
A2
L
A3
N
L
A1
L
A2
L
A3
N
For model WH-SHF12F9E8
1
1
2
2
3
3
4
4
5
5
L
B1
L
B2
L
B3
N
L
B1
L
B2
L
B3
N
L
A1
L
A2
L
A3
N
L
A1
L
A2
L
A3
N
LN
11
N L
N L
22
POWER SUPPLY 2
LB1 LB2 LB3 N
POWER SUPPLY 1
LA1 LA2 LA3 N
45
A
Terminal block strip
Indoor unit / outdoor unit
Connection of indoor unit
and outdoor unit
1
2
Terminals on indoor unit
Terminals on outdoor unit
Terminals on disconnector of the mains connection
1
2
3
For model WH-SHF09F3E8
1
1
2
2
3
3
4
4
5
5
L
L
N
N
L
A1
L
A2
L
A3
N
L
A1
L
A2
L
A3
N
For model WH-SHF12F9E8
1
1
2
2
3
3
4
4
5
5
L
B1
L
B2
L
B3
N
L
B1
L
B2
L
B3
N
L
A1
L
A2
L
A3
N
L
A1
L
A2
L
A3
N
LN
11
N L
N L
22
P OWER S UPPLY 2
L B1 LB2 L B3 N
P OWER S UPPLY 1
L A1 LA2 L A3 N
A
1 2 3 4 5

Table of Contents

Related product manuals