EasyManua.ls Logo

Panasonic CS-A18DKD

Panasonic CS-A18DKD
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Auto Airflow Direction:-
Rpm control depends on the piping air temperature sensor of Indoor heat exchanger
Quiet operation stops when:-
Quiet/Powerful button is pressed again.
Stopped by OFF/ON operation button.
Timer OFF activates.
Operating mode is changed.
8.12. Ionizer Operation
The Ionizer operation is to provide fresh air effect to user by producing minus ion in discharge air.
8.12.1. Operation Control
1. Ionizer individual operation
a. When air-conditioner unit is at “OFF” condition (standby) and ION operation button at the remote control is pressed, the
Ionizer and Air Circulation operations will turn on. Only ION LED will illuminates. Power LED maintain off. (1 2)
b. Ionizer individual operation can be turned off by pressing the ION button again. (2 1)
c. Fan speed can be adjusted later by customer during this operation.
32
CS-A18DKD CU-A18DKD / CS-A24DKD CU-A24DKD

Table of Contents

Related product manuals