Service Manual
Room Air Conditioners
Contents
Features ..........................................................1
Functions ...................................................2 – 4
Product Specifications ...............................5 – 8
Dimensions ..............................................9 – 10
Refrigeration Cycle Diagram .........................10
Block Diagram ............................................... 11
Wiring Diagram ..............................................12
Operation Details ...................................13 – 22
Installation Information ..........................23 – 24
3-way Valves ......................................... 25 – 31
Servicing Information .............................32 – 35
Troubleshooting Guide .......................... 36 – 37
Technical Data.......................................38 – 40
Exploded View .........................................41, 43
Replacement Parts List ...........................42, 44
Electronic Parts List ...............................45 – 46
CS-A181KR / CU-A181KR
CS-A241KR / CU-A241KR
ORDER NO. MAC9903022C3
1999 Matsushita Air-Conditioning Corp. Sdn. Bhd.
(183914D)
All rights reserved. Unauthorized copying and distribu-
tion is a violation of law.
Untitled-5 6/10/00, 3:21 PM1

Questions and Answers

  • S
    smithmichaelAug 11, 2025
    What to do if Panasonic Air Conditioner electric current reaches a high level abnormally?
    • I
      Ivan CookAug 11, 2025
      If the electric current of your Panasonic Air Conditioner reaches a high level abnormally, the compressor might be locked. In this case, you should check the condition of the compressor.
  • S
    shawwilliamAug 17, 2025
    What to do if my Panasonic Air Conditioner condenser is dusty and preventing heat radiation?
    • J
      Jordan JohnsonAug 18, 2025
      If the condenser of your Panasonic Air Conditioner is dusty and preventing heat radiation, you should clean the condenser.
  • J
    Jerry HarrisAug 23, 2025
    What to do if my Panasonic Air Conditioner has an excessive amount of refrigerant?
    • J
      Jane KhanAug 23, 2025
      If your Panasonic Air Conditioner has an excessive amount of refrigerant, you should reduce the amount of refrigerant.
  • A
    Andrew WrightAug 28, 2025
    Why is the electric current of my Panasonic CS-A181KR Air Conditioner 80% lower than normal during operation?
    • A
      Aaron WilsonAug 28, 2025
      If the electric current during operation is approximately 80% lower than the normal value for your Panasonic Air Conditioner, it may be due to inefficient switches of the 4-way valve. You should check the 4-way valve.
  • G
    Gary JonesSep 4, 2025
    Why is the electric current of my Panasonic CS-A181KR 20% lower than normal during operation?
    • S
      sbrownSep 4, 2025
      If the electric current during operation is approximately 20% lower than the normal value for your Panasonic Air Conditioner, it may be caused by insufficient compressing of a compressor. In this case, you should check the compressor.

Panasonic CS-A181KR Specifications

General IconGeneral
Power Supply220-240V, 50Hz
RefrigerantR410A
Weight (Indoor Unit)9 kg
Noise Level (Outdoor)48 dB
TypeSplit
Coefficient of Performance (COP)3.21 W/W
Outdoor Unit Dimensions (W x H x D)780 x 540 x 260 mm