– 38 –
MAC9512086C2
CS-A181KR
30
TC SHC IP
6.08 5.52 2.10
6.76 4.84 2.12
7.50 4.53 2.14
Technical Data
LL
LL
L Thermostat characteristics
CS-A181K / CS-A241K
Cooling
Soft Dry Heating
Cooling
Indoor Wet
Bulb Temp.
17.0°C
19.0°C
19.5°C
22.0°C
30
TC SHC IP
5.10 4.63 2.01
5.67 4.06 2.04
6.29 3.80 2.06
35
TC SHC IP
4.78 4.47 2.17
5.20 2.19
5.30 3.80 2.19
5.88 3.33 2.21
40
TC SHC IP
4.47 4.16 2.32
4.94 3.74 2.34
5.46 2.96 2.39
46
TC SHC IP
4.06 3.59 2.50
4.52 3.59 2.52
4.99 2.60 2.56
Outdoor Temp.(°C)
Cooling
Indoor Wet
Bulb Temp.
17.0°C
19.0°C
19.5°C
22.0°C
30
TC SHC IP
6.32 5.74 2.83
7.03 5.03 2.86
7.80 4.71 2.90
35
TC SHC IP
5.93 5.55 3.05
6.45 3.08
6.58 4.71 3.08
7.29 4.13 3.11
40
TC SHC IP
5.55 5.16 3.26
6.13 4.64 3.30
6.77 3.68 3.36
46
TC SHC IP
5.03 4.45 3.51
5.61 4.45 3.54
6.19 3.23 3.60
Outdoor Temp.(°C)
Heating
Indoor Wet
Bulb Temp.
17.0°C
19.0°C
19.5°C
22.0°C
30
TC SHC IP
7.64 6.94 2.91
8.50 6.08 2.94
9.44 5.69 2.97
35
TC SHC IP
7.18 6.71 3.13
7.80 3.16
7.96 5.69 3.16
8.81 4.99 3.19
40
TC SHC IP
6.71 6.24 3.35
7.41 5.62 3.38
8.19 4.45 3.44
46
TC SHC IP
6.08 5.38 3.60
6.79 5.38 3.63
7.49 3.90 3.70
Outdoor Temp.(°C)
Heating
Indoor Wet
Bulb Temp.
17.0°C
19.0°C
19.5°C
22.0°C
35
TC SHC IP
5.70 5.33 2.26
6.20 2.28
6.32 4.53 2.28
7.01 3.97 2.30
40
TC SHC IP
5.33 4.96 2.42
5.89 4.46 2.44
6.51 3.53 2.49
46
TC SHC IP
4.84 4.28 2.60
5.39 4.28 2.62
5.95 3.10 2.67
Outdoor Temp.(°C)
16
16
(°C)
Thermostat Setting (Remote Control)
Intake Air Temperature
18 28
2624
2220
30
18
20
22
24
26
28
30
32
34
(°C)
COMP. ONCOMP. ON
COMP. OFF
= Set Temperature
COMP. OFF
= Set Temperature
Diff. 1.5°CDiff. 1.5°C
16
(°C)
Thermostat setting (remote control)
18
2826
2422
20
30 (°C)
16
18
28
26
24
22
20
30
32
34
Intake Air Temperature
/
/
COMP. OFF = SET TEMPERATURE
COMP. ON
Diff. 2.0°C
COMP. OFF = SET TEMPERATURE
COMP. ON
Diff. 2.0°C
16
16
(°C)
Intake Air Temperature
Diff. 1.0°C
Cooling ON
Soft Dry OFF, Soft Dry ONSoft Dry OFF, Soft Dry ON
Diff. 1.5°C
Diff. 1.0°C
Thermostat Setting (Remote Control)
34
24
22
20
18
28
26
30
32
18 20
22
24
26
28 30 (°C)
Cooling ON
Soft Dry OFF, Soft Dry ON
Diff. 1.5°C
Cooling OFF
= Set Temperature
Cooling OFF
= Set Temperature
LL
LL
L Sensible Capacity Chart
CS-A181K
TC – Total Cooling / Heating Capacity (kW) Indoor 27°C/19°C
SHC – Sensible Heat Capacity (kW) Outdoor 35°C/24°C
IP - Input Power (kW)
CS-A241K
Untitled-4 6/10/00, 3:18 PM38