11.13. Random Auto Restart Control
If there is a power failure during operation, the air conditioner will automatically restart after 3 to 4 minutes when the power is
resumed.
It will start with previous operation mode and airflow direction.
If there are more than one air conditioner unit in operation and power failure occur, restart time for each unit to operate will be
decided randomly using 4 parameters:- intake air temperature, setting temperature, fan speed and air swing louver position.
This Random Auto Restart Control is not available when Timer is set.
This control can be omitted by open the circuit of JX02. (Refer printed circuit board indoor unit)
11.14. Remote Control Signal Receiving Sound
Long beep sound will be heard when:
- Stopping the air conditioner using ON/OFF switch.
Short beep sound will be heard for others setting.
11.15. Auto Refresh Deo
Deodorizing Blue LED (Auto refresh Deo) is ON for 30 min only once air conditioner is ON; after 30 min it will be off.
In case the air conditioner is ON continuously for more that 24h, then the Deodorizing Blue LED will be reactive again after 24h x
n (n = 1,2,3,4 etc.) for 30 min each.