12.15. Patrol Operation
1. Purpose
To monitor air dirtiness level by using gas sensor and activates e-ion operation whenever air is dirty.
2. Control Condition
a. Patrol operation start condition
When the unit operation is started with “OFF/ON” button.
When the unit stops, “Patrol” button is pressed, Patrol individual operation will start.
During cooling only operation, “Patrol” button is pressed.
b. Patrol operation stop condition
When any of the following condition is fulfilled:
When “OFF/ON” button is pressed.
During any operation with Patrol, "Patrol" button is pressed again.
When “e-ion” button is pressed.
When OFF Timer activates.
c. Patrol operation disable
To disable the Patrol Operation during unit start (default) with “OFF/ON” button, press “Patrol” button and hold for 5
seconds, then release.
To disable the Patrol Operation, press “Patrol” button and hold for 15 seconds, then release.