g. Error Detection Control
When e-ion indicator blink, it indicates error listed below:
a. e-ion AIR PURIFYING SYSTEM main connector to PCB is open:
Judgment Method
During e-ion operation (include during Patrol operation), e-ion AIR PURIFYING SYSTEM main connector to PCB is
opened.
Troubleshooting Methods
Connect the connector or stop operation (include during Patrol operation) to cancel the blinking.
b. Abnormal Discharge
Judgment Method
During e-ion operation, when feedback voltage is-Lo (at micro controller) is detected, it is judged abnormal discharge and
stops power supplies to the e-ion AIR PURIFYING SYSTEM.
The unit retries after 30 minutes and repeat for 24 times. (not applicable for e-ion Check Mode)
Troubleshooting Method
Press “e-ion” button or “OFF/ON” button to stop the operation and check the e-ion AIR PURIFYING SYSTEM main
connector to PCB.
After that, press “e-ion” button again to confirm the e-ion indicator not blinking.
The 24 times counter will be clear after 10 minutes of normal operation or when operation stops.
Error Reset Method
Press “OFF/ON” button to OFF the operation.
Press AUTO OFF/ON button at indoor unit to OFF the operation.
OFF Timer activates.
Press “e-ion” button during e-ion individual mode.
Power supply reset.
c. e-ion breakdown
Judgment Method
When hi-feedback voltage (at micro controller) supplied to filter during e-ion stop, due to PCB or filter's high voltage power
supply damage.
Operations except e-ion continue. Both Timer indicator and e-ion indicator blinks.
Troubleshooting Method
Press “e-ion” button or “OFF/ON” button to stop the operation.
Change main circuit board or filter's high voltage power supply.
When lo-feedback voltage supplied to e-ion AIR PURIFYING SYSTEM during e-ion operation, e-ion indicator and Timer
indicator stop blinking.