12.4 Indoor Fan Speed Control
• Indoor fan speed can be set using remote control.
12.4.1 Fan Speed Rotation Chart
Fan Speed (rpm)
Speed
CS-C9KKV CS-C12KKV
Shi 1130 1130
Hi 1030 1110
Me 850 930
HLo 690 790
CLo 650 750
Lo- 610 710
SLo 590 690
Qhi 960 1040
QMe 780 860
QLo 580 680
Fan Speed (rpm)
Speed
CS-C18KKV CS-C24KKV CS-C28KKV
Shi 1390 1500 1530
Hi 1240 1350 1490
Me 1140 1230 1400
HLo 1130 1190 1330
CLo 1050 1110 1250
Lo- 850 970 1050
SLo 670 750 830
Qhi 1150 1150 1400
QMe 1050 1050 1310
QLo 960 960 1160
12.4.2 Automatic Fan Speed Control
• When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the
table.
o Fan speed rotates in the range of Hi and Me (For CS-C9KK and CS-C12KK).
o Fan speed rotates in the range of Hi, Me and Lo- (For CS-C18KK, CS-C24KK and CS-C28KK).
o Deodorizing Control will be activated.
For CS-C9KK and CS-C12KK
SHi Hi Me HLo CLo Lo- SLo
Variable
rpm
Stop
Hi o
Me o
Manual
Lo o
Normal
Auto o o o o o
QHi
Hi-
70
QMe
Me-
70
Manual
QLo
CLo-
70
Quiet
Auto
Hi-
70
Me-
70
o o o
Manual o
Cooling
Powerful
Auto o
Manual o o
Normal
Auto o o
Manual o o
Quiet
Auto o o
Manual o o
Soft Dry
Powerful
Auto o o