91
17.1.3 CS-C18KKV CU-C18KKV
Cooling Characteristic
o Room temperature: 27°C (DBT), 19°C (WBT)
o Operation condition: High fan speed
o Piping length: 7.5m
Current (A)
Gas Side
Piping Pressure (MPa)
Capacity (kW)Outlet Air (ºC)
Outdoor Temperature (ºC)
Outdoor Temperature (ºC)
Outdoor Temperature (ºC)
Outdoor Temperature (ºC)
30 32 34 36 38 40
30 32 34 36 38 40
30 32 34 36 38 40
30 32 34 36 38 40
220V
220V
220V
220V
14.30
14.50
14.70
14.90
15.10
15.30
4.90
5.10
5.30
5.50
5.70
7.40
7.60
7.80
8.00
8.20
8.40
8.60
0.440
0.450
0.460
0.470
0.480

Table of Contents