8 Wiring Connection Diagram
8.1. CS-C18GK CU-C18GK
Resistance of Outdoor Fan Motor Windings
Note: Resistance at 25°C of ambient temperature.
Resistance of Compressor Windings
Note: Resistance at 20°C of ambient temperature.
MODEL CU-C18GK
CONNECTION CWA951120J
BLUE-YELLOW 200.4 Ω
YELLOW-RED 252.5 Ω
MODEL CU-C18GK
CONNECTION 2KS324D5DA04
C - R 1.396 Ω
C - S 2.379 Ω