EasyManua.ls Logo

Panasonic CS-C18GKF

Panasonic CS-C18GKF
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32
2. Norrowing
Vertical Airflow Direction
During dew prevention control, Airflow Direction Auto-control angle change from 10° - 38° to 10° - 27° under
Cooling and Soft Dry operation mode.
During dew prevention control, Airflow Direction Manual control angle change from 10°, 14°, 18°, 22°, 27° to
10°, 13°, 16°, 19°, 22° under Cooling and Soft Dry operation mode.
3. Narrowing
Horizontal Airflow Direction
During dew prevention control, Airflow Direction Auto-control angle change form 0° - 44° to 14° - 30° under
Cooling and Soft Dry operation mode.
During dew prevention control, Airflow Direction Manual control angle change from 0°, 11°, 22°, 33°, 44° to
14°, 18°, 22°, 26°, 30° under Cooling and Soft Dry operation mode.

Related product manuals