40
3. Control Content
a. Gas Sensor Control
First 2 minutes from Patrol function activates is stabilization time, during stabilization time, no air dirtiness level is
monitored. The Air Dirtiness level is set to level 2.
After that, gas sensor starts to record the resistance value at fixed interval. Higher resistance value indicates cleaner air.
The air dirtiness level is monitored by comparing the current resistance value with maximum resistance value from time to
time to get the Air Dirtiness Value.
There are 3 air dirtiness level, based on the Air Dirtiness Value:
- Air Dirtiness level 0: Clean
- Air Dirtiness level 1: Moderate
- Air Dirtiness level 2: Contaminated
- Dirtiness level sensitivity adjustment.
It is possible to change the gas sensor sensitivity, where the Threshold value (G1 ~ G4) will be shifted accordingly:
a. Press and release “SET” button.
b. Press “Timer increment” / “Timer decrement” button to select sensitivity. (Low <
> Standard (Default) <> High)
c. Confirm setting by pressing “Timer Set” button. LCD returned to original display after 2 seconds.
d. LCD returned to original display if remote control does not operate for 30 seconds.
b. e-ion Control
When dirtiness level is 1 or 2, e-ion operation starts.
If dirtiness level improves from level 2 to level 1, the unit carries out level change after 60 seconds.
When dirtiness level returns to level 0 continuously for 10 minutes or more, e-ion operation stops.
Dirtiness Level Shift
For Auto Fan Speed, the fan speed increased based on dirtiness level: