9.2.5. CONNECT THE CABLE TO THE
INDOOR UNIT
1. The inside and outside connecting cable can be connected
without removing the front grille.
2. Connecting cable between indoor unit and outdoor unit
shall be approved polychloroprene sheathed 5
(YW9DKE,YW12DKE) x 1.5 mm
2
flexible cord, type
designation 245 IEC 57 or heavier cord.
ı
ıı
ıˇı
ˇıˇı
ˇı
Ensure the color of wires of outdoor unit and the
terminal Nos. are the same to the indoor’s respectively.
ı
ıı
ıˇı
ˇıˇı
ˇı
Earth lead wire shall be longer than the other lead wires
as shown in the figure for the electrical safety in case of
the slipping out of the cord from the anchorage.
ı
ıı
ıˇı
ˇıˇı
ˇı
Secure the cable onto the control board with the holder
(clamper).