Notes:
9.1.1.7. Indoor Fan Motor Operation
A. Basic Rotation Speed (rpm)
Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit)
[Cooling, Dry, Fan]
Remote Control O O O O O
Tab (rpm) PSHi SHi Hi Me+ Me Me- Lo Lo- SLo SSLo
CS-ME7DKEG 1320 1320 1280 1210 1040 970 920 860 720 710
CS-E9DKEW 1320 1320 1280 1210 1040 970 920 860 720 710
CS-E12DKEW 1460 1460 1420 1320 1220 1120 1020 950 720 710
CS-E15DKEW 1500 1500 1460 1350 1240 1130 1020 950 720 710
CS-E18DKEW 1540 1540 1450 1340 1240 1140 1040 980 770 640
[Heating]
Remote Control O O O O O
Tab (rpm) PSHi SSHi SHi Me+ Me Me- Lo Lo- SLo SSLo
CS-ME7DKEG 1440 1440 1400 1290 1170 1060 950 870 720 710
CS-E9DKEW 1440 1440 1400 1290 1170 1060 950 870 720 710
CS-E12DKEW 1540 1540 1500 1400 1290 1180 1070 990 720 710
CS-E15DKEW 1570 1570 1560 1430 1310 1190 1070 990 720 710
CS-E18DKEW 1640 1640 1580 1470 1350 1230 1110 1040 400 300
1. Refer to the CS-ME7DKEG column for CS-ME7DKRG and CS-ME7DKDG.
2. Refer to the CS-E9DKEW column for CS-E9DKRW and CS-E9DKDW.
3. Refer to the CS-E12DKEW column for CS-E12DKRW and CS-E12DKDW.
4. Refer to the CS-E15DKEW column for CS-E15DKRW and CS-E15DKDW.
5. Refer to the CS-E18DKEW column for CS-E18DKRW and CS-E18DKDW.
42
CS-ME7DKEG CS-ME10DD3 EG / CS-ME10DTEG CS-E15DB4EW