9.4.1.3. Cooling Operation
9.4.1.3.1. Thermostat control
Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -1.5°C.
Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature > Compressor OFF
point.
9.4.1.4. Soft Dry Operation
9.4.1.4.1. Thermostat control
Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -2.0°C.
Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature > Compressor OFF
point.
9.4.1.5. Heating Operation
9.4.1.5.1. Thermostat control
Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < +2.0°C.
Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature > Compressor OFF
point.
77