9
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6°C W.B. (42.8°F W.B.)
Note
• Specifications are subject to change without notice for further improvement.
Heat Exchanger
Fin Material Aluminium (Pre Coat) Aluminium (Blue Coat)
Fin Type Slit Fin Corrugated Fin
Row x Stage x FPI 2 x 15 x 21 2 x 24 x 17
Size (W x H x L) mm 610 x 315 x 25.4
36.4 x 504 x 713
684
Air Filter
Material Polypropelene —
Type One-Touch —
Item Unit
Power Source (Phase, Voltage, Cycle)
ø Single
V 220 - 230
Hz 50
Input Power W
Cooling; 950 (185 ~ 1200)
Heating; 1280 (175 ~ 1910)
Starting Current A 6.1
Running Current A
Cooling; 4.6 - 4.4
Heating; 6.1 - 5.9
Power Factor %
Cooling; 94 - 94
Heating; 95 - 94
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
*Maximum over current protection A 8.8
Power Cord
Number of core —
Length m —
Thermostat Electronic Control
Protection Device Electronic Control
ITEM UNIT INDOOR UNIT OUTDOOR UNIT